Specifications

Power

Redundant Input power

Dual DC inputs.  12~48VDC on 4 pin terminal block

* Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 power supply only.
* Fourni par la source SELV évaluée uniquement par l'alimentation UL 61010-1 or

61010-2-201.

Physical Characteristic

Enclosure

IP-30 Metal (non UL certified)

Dimension (W x D x H)

26(W)x75(D)x110(H) mm (1.02 x 2.95 x 4.33 inch.)

Weight (g)

Environmental

-40 to 85 C (-40 to 185 F)

o

o

Storage Temperature

5% to 95% Non-condensing

Operating Humidity

Regulatory Approvals

FCC Part 15B, CISPR 32 (EN55032 class A)

EMI

EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (CS)
EN61000-4-8
EN61000-4-11

EMS

IEC60068-2-27

Shock

IEC60068-2-32

IEC60068-2-6

Vibration

Free Fall

Warranty

5 years

RS-232

Flow Control

EN60950-1, UL61010-1, UL61010-2-201

Safety

-40 to 70 C (-14 to 140 F)

o

o

Operating Temperature

ORing Device Server
Model

10/100Base-T(X) Ports in Auto
MDI/MDIX

2

Physical Ports

Technology

Stop Bits

Network Protocol

Data Bits

IDS-312L

1, 1.5, 2

TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

227g

XON/XOFF, RTS/CTS, DTR/DSR

7, 8

Power Consumption(Typ.)

0.05A-0.1A

Overload current protection

Present

Reverse polarity protection

Present

Version 1.2

Serial Ports

Connector

DB9 x 1

Operation Mode

Serial Baud Rate

110 bps to 921.6 Kbps

RS-232/422/485

Industrial Device Server

Device
Server

For pin assignments for different types of cables, please refer to the following
tables.

10/100 Base-T(X) RJ-45

Pin Number

MDI port

MDI-X port

1

TD+(transmit)

RD+(receive)

2

TD-(transmit)

RD-(receive)

3

RD+(receive)

TD+(transmit)

4

Not used

Not used

5

Not used

Not used

6

RD-(receive)

TD-(transmit)

7

Not used

Not used

8

Not used

Not used

10/100 Base-T(X) RJ-45

Pin Number

Assignment

1

TD+

2

TD-

3

RD+

4

Not used

5

Not used

6

RD-

7

Not used

8

Not used

Note:

“+” and “-” signs represent the polarity of the wires that make up each wire pair

.

DB9 serial port

The device can be connected to a serial device using a DB9
cable. The DB9 connector supports RS232 / RS422 / RS485
operation modes. Please refer to the following table for the pin
assignments of the DB9 connector.

5 4 3 2 1

9 8 7 6

DB9 male connector

Wiring

This device supports dual redundant power supplies, Power Supply
1 (PWR1) and Power Supply 2 (PWR2). The connectors for PWR1
and  PWR2  are located on the terminal block.

STEP 1:

Insert

the

negative/positive

DC

wires

into

the

V-/V+

terminals,  respectively.

STEP 2:

To keep the DC wires from pulling loose, use a small flat-

blade screwdriver to tighten the wire-clamp screws on the front of
the  terminal  block  connector.

Power inputs

Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.

Grounding

Configurations

After installing the device and connecting cables, the green power LED should turn on.
Please refer to the following table for LED indication.

PWR-1

PWR-2

V1+

V1-

V2+

V2-

1. Launch the Internet Explorer and type in IP address of the device. The default static IP address is

192.168.10.2

Follow the steps below to log in and access the system:

Resetting

To restore the device  configurations  back  to  the  factory  defaults,  press  the

button  for  a  few

Reset

seconds.  Once  the  power  indicator  starts  to  flash,  release  the  button.  The  device  will  then  reboot
and  return  to  factory  defaults.

Protocol

ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP, V1/V2c, HTTPS, SMTP

RS-422

Tx-, Tx+, Rx+, Rx-

RS-485

4 wire: Tx-, Tx+, Rx+, Rx-
2 wire: Data-, Data

LED

Color

Status

Description

PWR 1/2

Green

On

Power is on and function normally

ETH 1/2

Green

On

Port is connected

Blinking

Data Transmitted

RX / TX

Amber

On

Receiving Serial data

Green

On

Transmitting Serial data

Dip Switch

SW No.

Description

#1

150K / 1K Ohm Pull High/Low Resistor

#2

#3

Enable / Disable Terminal Resistor

Pin #

RS-232

RS-422

RS-485

( 4 wire )

RS-485

( 2 wire )

1

DCD

TX-

TX-

2

RXD

TX+

TX+

3

TXD

RX+

RX+

DATA+

4

DTR

RX-

RX-

DATA-

5

GND

GND

GND

GND

6

DSR

7

RTS

8

CTS

Pull
Hi
/Low

Term.
Res.

IDS-312L

IDS-312L

Parity

odd, even, none, mark, space

2. Log in with the default user name “admin” and password is “admin” also. however, you can set
up a password later in the management page. After logging in, you should see the following
screen. For more information on configurations, please refer to the user manual. For information on
operating the device server using ORing’s DS-Tool management utility, please go to ORing website.

*****

ORing Industrial Networking Corp.

Copyright©  2017 ORing

All rights reserved.

TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F

No 542 2 Zhongzheng Rd

Xindian Dist

New

:

.,

.

- ,

.,

.,

Taipei City 23148 Taiwan

,

Website: www.oringnet.com
E-mail: [email protected]

Contact for maintenance and repair service:

Up to 2000m

Operating Altitude

Warning [AVERTISSEMENT]

Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]