Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
Q I G
Specifications
Power
Redundant Input power
Dual DC inputs. 12~48VDC on 4 pin terminal block
* Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 power supply only.
* Fourni par la source SELV évaluée uniquement par l'alimentation UL 61010-1 or
61010-2-201.
Physical Characteristic
Enclosure
IP-30 Metal (non UL certified)
Dimension (W x D x H)
26(W)x75(D)x110(H) mm (1.02 x 2.95 x 4.33 inch.)
Weight (g)
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory Approvals
FCC Part 15B, CISPR 32 (EN55032 class A)
EMI
EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-4 (EFT)
EN61000-4-5 (Surge)
EN61000-4-6 (CS)
EN61000-4-8
EN61000-4-11
EMS
IEC60068-2-27
Shock
IEC60068-2-32
IEC60068-2-6
Vibration
Free Fall
Warranty
5 years
RS-232
Flow Control
EN60950-1, UL61010-1, UL61010-2-201
Safety
-40 to 70 C (-14 to 140 F)
o
o
Operating Temperature
ORing Device Server
Model
10/100Base-T(X) Ports in Auto
MDI/MDIX
2
Physical Ports
Technology
Stop Bits
Network Protocol
Data Bits
IDS-312L
1, 1.5, 2
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
227g
XON/XOFF, RTS/CTS, DTR/DSR
7, 8
Power Consumption(Typ.)
0.05A-0.1A
Overload current protection
Present
Reverse polarity protection
Present
Version 1.2
Serial Ports
Connector
DB9 x 1
Operation Mode
Serial Baud Rate
110 bps to 921.6 Kbps
RS-232/422/485
Industrial Device Server
Device
Server
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) RJ-45
Pin Number
MDI port
MDI-X port
1
TD+(transmit)
RD+(receive)
2
TD-(transmit)
RD-(receive)
3
RD+(receive)
TD+(transmit)
4
Not used
Not used
5
Not used
Not used
6
RD-(receive)
TD-(transmit)
7
Not used
Not used
8
Not used
Not used
10/100 Base-T(X) RJ-45
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
Note:
“+” and “-” signs represent the polarity of the wires that make up each wire pair
.
DB9 serial port
The device can be connected to a serial device using a DB9
cable. The DB9 connector supports RS232 / RS422 / RS485
operation modes. Please refer to the following table for the pin
assignments of the DB9 connector.
5 4 3 2 1
9 8 7 6
DB9 male connector
Wiring
This device supports dual redundant power supplies, Power Supply
1 (PWR1) and Power Supply 2 (PWR2). The connectors for PWR1
and PWR2 are located on the terminal block.
STEP 1:
Insert
the
negative/positive
DC
wires
into
the
V-/V+
terminals, respectively.
STEP 2:
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of
the terminal block connector.
Power inputs
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the device and connecting cables, the green power LED should turn on.
Please refer to the following table for LED indication.
PWR-1
PWR-2
V1+
V1-
V2+
V2-
1. Launch the Internet Explorer and type in IP address of the device. The default static IP address is
192.168.10.2
Follow the steps below to log in and access the system:
Resetting
To restore the device configurations back to the factory defaults, press the
button for a few
Reset
seconds. Once the power indicator starts to flash, release the button. The device will then reboot
and return to factory defaults.
Protocol
ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP, V1/V2c, HTTPS, SMTP
RS-422
Tx-, Tx+, Rx+, Rx-
RS-485
4 wire: Tx-, Tx+, Rx+, Rx-
2 wire: Data-, Data
LED
Color
Status
Description
PWR 1/2
Green
On
Power is on and function normally
ETH 1/2
Green
On
Port is connected
Blinking
Data Transmitted
RX / TX
Amber
On
Receiving Serial data
Green
On
Transmitting Serial data
Dip Switch
SW No.
Description
#1
150K / 1K Ohm Pull High/Low Resistor
#2
#3
Enable / Disable Terminal Resistor
Pin #
RS-232
RS-422
RS-485
( 4 wire )
RS-485
( 2 wire )
1
DCD
TX-
TX-
2
RXD
TX+
TX+
3
TXD
RX+
RX+
DATA+
4
DTR
RX-
RX-
DATA-
5
GND
GND
GND
GND
6
DSR
7
RTS
8
CTS
Pull
Hi
/Low
Term.
Res.
IDS-312L
IDS-312L
Parity
odd, even, none, mark, space
2. Log in with the default user name “admin” and password is “admin” also. however, you can set
up a password later in the management page. After logging in, you should see the following
screen. For more information on configurations, please refer to the user manual. For information on
operating the device server using ORing’s DS-Tool management utility, please go to ORing website.
*****
ORing Industrial Networking Corp.
Copyright© 2017 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Address 3F
No 542 2 Zhongzheng Rd
Xindian Dist
New
:
.,
.
- ,
.,
.,
Taipei City 23148 Taiwan
,
Website: www.oringnet.com
E-mail: [email protected]
Contact for maintenance and repair service:
!
Up to 2000m
Operating Altitude
!
Warning [AVERTISSEMENT]
Take into consideration the following guidelines before wiring the device
[Tenez compte des directrices suivantes avant de câbler l’appareil.]
1. Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
[Le bornier est compatible avec les connecteurs et convient pour 12-24AWG.
Valeur de couple 4,5 lb-in.]
2. The temperature rating of the input connection cable should higher than 105°C
[La température de service nominale du câble d’entrée doit être supérieure à 105 °C]