16
1, Automatic mode
(blue indicator light):
Automatic mode is the default mode when the machine is turn on. The the default setting humidity data is
60%RH
Under this mode, the indicator light of mode button will be blue color and the
fan speed will be switched
according to the change of room humidity level.
If room humidity ≥ setting humidity data (+3%) , the compressor will start to work
If room humidity < setting humidity data (-3%) , the compressor will stop working ,and the fan will stop
working after 30 seconds later
If the room humidity is higher than the setting humidity data, and difference is more than 10%RH (+3%) ,the
fan speed will switch to high fan speed automatically
If the room humidity is higher than the setting humidity data, but difference is less than 10%RH (-3%) ,the fan
speed will switch to low fan speed automatically
Under this mode, the fan speed will be switched automatically and the humidity setting funciton is
effective.You can just only set the humidity data
2, Common mode
(purple indicator light)
Press mode button to switch to common mode. The indictaor light of mode button will be purple color under
this mode.The machine will work as below :
If room humidity ≥ setting humidity data (+3%) , the compressor will start to work
If room humidity < setting humidity data (-3%) , the compressor will stop working ,and the fan will stop
working after 30 seconds later
Under common mode , the humidity setting and the fan speed setting function are effective ,you can set
humidity data and fan speed.
3, Continuously dehumidify mode
(orange indicator light).
Press mode button to switch to continuously dehumidify mode and the indicator light of mode button will be
orange color
Under this mode , the default humidity data is 20%RH , and the fan speed is high fan speed . The humidity
setting function and fan speed settting function is ineffective , you can not set the humidity data and fan
speed