background image

Convenient functions

20

6.3  Data locking for the set data

The data setting can be locked so that the set rotation speed and 

parameters do not change.
The setting of data and parameters cannot be changed using the setting 

dial while the data is locked.

However, the setting data of each parameter can be checked even when 

the data is locked.
Remove the front panel when executing the data locking.

ESC key

Rotation speed monitor 

Locking

Lock

Press and hold the ESC key
(about 5 seconds)

Rotation speed monitor 

Reset locking

Reset

Press and hold the ESC key
(about 5 seconds)

 

Display while the data is locked

If you try to change the data while the data is locked, "

" is displayed for about 1 second.

6.4  Display after setting the speed reduction ratio

 

„

Display position of decimal point

The position of the decimal point displayed on the rotation speed monitor varies depending on the set speed reduction ratio 
or speed increasing ratio as shown in the table below.

Setting value for the speed reduction 

ratio and speed increasing ratio

Display position of 

decimal point

1.00 to 9.99

10.00 to 99.99

100.0 to 999.9

1000 or more

 

„

Display the conveyor transfer speed

To display the conveyor transfer speed, set the conveyor speed reduction ratio, which is calculated using the formula below, 
to the "speed reduction ratio" parameter.

 

 79.6

Conveyor speed reduction ratio =

Gearhead gear ratio

Pulley diameter [m] × 

=

25

0.1 [m] × 

From the conversion formula, the conveyor speed reduction ratio is calculated as 79.6 in this example.

When the "speed reduction ratio" parameter is set to "79.60" and the motor rotation speed is 1300 r/min,

the conveyor transfer speed is converted as follows:

16.3

1300

79.60

Conveyor transfer speed [m/min] =

Accordingly, "16.3" is shown on the panel. The display varies depending on the setting of the "lowest digit display

fixing" parameter. 16.0 is displayed at the time of shipment.

Conveyor
transfer speed

Pulley
diameter

=

=

1

Feed rate per motor revolution

Gearhead gear ratio

Pulley diameter [m] × 

Conveyor transfer speed [m/min] =

Motor output shaft rotation speed [r/min]

Conveyor speed reduction ratio

When the calculated conveyor speed reduction ratio is used, 

the conveyor transfer speed is converted as follows:

Example: The pulley diameter is 0.1 m and gear ratio of the gear head is 25

Conveyor speed

reduction ratio

Summary of Contents for US2 Series

Page 1: ...procedures and safety precautions Please read it thoroughly to ensure safe operation Always keep the manual where it is readily available D loop represents the speed control motor which adopted Orien...

Page 2: ...lays and setting items 19 6 3 Data locking for the set data 20 6 4 Display after setting the speed reduction ratio 20 Display position of decimal point 20 Display the conveyor transfer speed 20 6 5 So...

Page 3: ...g a cable is attached Input signal terminal Function switching key Front panel Protective Earth Terminal Operating Connecting Connecting Convenient functions When the front panel is removed Motor cabl...

Page 4: ...company a Caution symbol may result in injury or property damage Do not use the motor and speed controller beyond their specifications Doing so may result in electric shock injury or damage to equipme...

Page 5: ...Number Length m of a supplied connection cable 1 1 m 3 3 ft 2 2 m 6 6 ft 3 3 m 9 8 ft Blank Without a supplied connection cable Number Gear ratio A Round shaft type Power supply voltage JA Single phas...

Page 6: ...0 UA Single phase 200 VAC US2 560JC o SCM560GVH JC US2D60 JC Single phase 220 230 VAC US2 560EC o SCM560GVH EC US2D60 EC 90 W Single phase 100 VAC US2 590JA o SCM590GVR JA 5GVRoB US2D90 JA Single phas...

Page 7: ...causes the motor to rotate Setting the operation switch to the STAND BY side causes the motor to stop FUNCTION key This key is used to switch the function Setting dial This setting dial is used to ch...

Page 8: ...s or vacuum Altitude Up to 1000 m 3300 ft above sea level 3 2 Installing the motor Installing the parallel shaft combination type Drill tapped holes in the mounting plate and secure the product with t...

Page 9: ...ng is attached to the flange of the motor Do not pinch the O ring when assembling the motor and gearhead Pinching the O ring causes a grease leak from the gearhead Output shaft pinion of motor Gearhea...

Page 10: ...with cooling fan 90 W When installing a motor with cooling fan onto a device leave 10 mm 0 39 in or more behind the fan cover or open a ventilation hole so that the cooling inlet on the back of the m...

Page 11: ...xcessive or abrupt force to the hollow output shaft when inserting a load shaft into the hollow output shaft Excessive or abrupt force may damage the gearhead internal bearings Installing the safety c...

Page 12: ...lb 10 mm 0 39 in 20 mm 0 79 in Distance from output shaft end Axial load Radial load 10 mm 0 39 in 20 mm 0 79 in SCM26 50 11 2 110 24 Not to exceed one half the motor s mass SCM315 40 9 60 13 5 SCM42...

Page 13: ...rder to keep within the operating ambient temperature Installation method Install the speed controller to a flat metal plate offering excellent vibration resistance Remove the front panel of the speed...

Page 14: ...voltage of the product Single phase 110 115 VAC 200 VAC 220 230 VAC Single phase 100 VAC Connect the live side to terminal L or L1 and the neutral side to terminal N or L2 Ground the speed controller...

Page 15: ...e not grounded Motor Ground close to the motor at a shortest distance using the Protective Earth Terminal of the motor Protective Earth Terminal Applicable crimp terminal Round crimp terminal with ins...

Page 16: ...rotation speed Operation switch STAND BY RUN When the setting dial is turned the display blinks and the motor rotation speed is changed The amount of the rotation speed change varies depending on the...

Page 17: ...r the motor rotates or stops 5 3 Switching the motor rotation direction The motor rotation direction can be changed with the rotation direction switch Rotation direction switch FWD REV Rotation direct...

Page 18: ...tting Prevention of operation at power on alarm oFF Disable on Enable on Sets whether to enable or disable the prevention of operation at power on alarm When starting and stopping the motor by ON OFF...

Page 19: ...BY the setting speed is displayed Rotation speed monitor Data setting The data can be locked so that the set value does not change Set on the rotation speed monitor screen If the ESC key is pressed an...

Page 20: ...mal point 1 00 to 9 99 10 00 to 99 99 100 0 to 999 9 1000 or more Display the conveyor transfer speed To display the conveyor transfer speed set the conveyor speed reduction ratio which is calculated...

Page 21: ...celeration time The acceleration time is set as the time needed for the motor to reach the 1000 r min from the standstill state Deceleration time The deceleration time is set as the time needed for th...

Page 22: ...for about 1 second ON OFF ON OFF REV input FWD input Motor movement Forward direction Reverse direction Operation standstill Operation standstill FWD input REV input Motor shaft action ON OFF Rotates...

Page 23: ...while the operation switch was set to the RUN side The power supply was turned on while the FWD input or REV input was being ON If the operation switch which is setting to the RUN side is set to the...

Page 24: ...ecified combination Check the tables on p 6 for the model name The motor rotates in the direction opposite to the specified direction The rotation direction switch is set to the opposite side Check th...

Page 25: ...roduct The speed controller uses semiconductor elements So be extremely careful when handling them Static electricity may damage the speed controller Inspection item Are the mounting screws of the mot...

Page 26: ...available Maximum extension distance between the motor and speed controller 10 5 m 34 4 ft including 0 5 m 1 6 ft of the motor cable Speed controller Up to 10 m 32 8 ft can be extended Up to 3 pieces...

Page 27: ...S2D15 JA SCM590JA GHRo SCM590HP JA US2D90 JA SCM315GV UA US2D15 UA SCM590JC GHRo SCM590HP JC US2D90 JC SCM315GV JC US2D15 JC SCM425JA GARo SCM425HP JA US2D25 JAB SCM315GV EC US2D15 EC SCM425JC GARo SC...

Page 28: ...osure whose degree of protection is equivalent to IP54 or higher and supply a rated voltage via the insulation transformer The motor temperature rise tests Temperature rise tests required by the above...

Page 29: ...ing methods will enable the product to be compliant with the EMC Directive Connecting mains filter for AC power supply line Install a mains filter which the customer provides in the power line in orde...

Page 30: ...Use a connection cable supplied or accessory when extending the wiring distance between the motor and speed controller The EMC measures are conducted using the Oriental Motor connection cable Example...

Page 31: ...as the torque rotation speed etc of the products check the Oriental Motor Website or catalog General specifications Item Motor Speed controller Operation environment Ambient temperature Single phase...

Page 32: ...rd party products mentioned in this manual are recommended products and references to their names shall not be construed as any form of performance guarantee Oriental Motor is not liable whatsoever fo...

Reviews: