4
y
Unauthorized reproduction or copying of all or part of this manual is prohibited.
y
Oriental Motor shall not be liable whatsoever for any problems relating to industrial
property rights arising from use of any information, circuit, equipment or device
provided or referenced in this manual.
y
Characteristics, specifications and dimensions are subject to change without notice.
y
While we make every effort to offer accurate information in the manual, we welcome
your input. Should you find unclear descriptions, errors or omissions, please contact the
nearest office.
y
is a registered trademark or trademark of Oriental Motor Co., Ltd.,
in Japan and other countries.
© Copyright ORIENTAL MOTOR CO., LTD. 2016
Published in February 2018
Technical Support Tel:(800)468-3982
8:30
A.M.
to 5:00
P.M.
, P.S.T. (M-F)
7:30
A.M.
to 5:00
P.M.
, C.S.T. (M-F)
www.orientalmotor.com
Schiessstraße 44, 40549 Düsseldorf, Germany
Technical Support Tel:00 800/22 55 66 22
www.orientalmotor.de
Tel:01256-347090
www.oriental-motor.co.uk
Tel:01 47 86 97 50
www.orientalmotor.fr
Tel:02-93906346
www.orientalmotor.it
Tel:+55-11-3266-6018
www.orientalmotor.com.br
• Please contact your nearest Oriental Motor office for further information.
4-8-1Higashiueno,Taito-ku,Tokyo 110-8536
Japan
Tel:03-6744-0361
www.orientalmotor.co.jp
Tel:0800-060708
www.orientalmotor.com.tw
Singapore
Tel:1800-8420280
www.orientalmotor.com.sg
Tel:1800-806161
www.orientalmotor.com.my
Korea
Tel:080-777-2042
www.inaom.co.kr
Tel:1800-888-881
www.orientalmotor.co.th
Tel:400-820-6516
www.orientalmotor.com.cn
Tel:+91-80-41125586
www.orientalmotor.co.in
Hong Kong Branch
Tel:+852-2427-9800
•
How to calculate loads
Use the calculating formula below for the axial load and moment load.
Example 1; When an external force F is applied on the position of distance
L from the center of the output flange
Axial load: Fs [N] = F + mg (Load mass)
Moment load:
∆
M [N·m] = F × L
F [N]
L [m]
Load mass m [kg]
mg
Fulcrum
Moment load
∆
M [N·m]
Example 2; When external forces F1 and F2 are applied on the position of
distance L from the mounting face of the output flange
Axial load: Fs [N] = F1 + mg (Load mass)
Moment load:
∆
M [N·m] = F2 × (L + constant a) *
* Motor frame size
51 mm (2.01 in.): a = 0.0129
Motor frame size ø72 mm (2.83 in.): a = 0.0095
F2 [N]
F1 [N]
L [m]
Constant a [m]
Load mass m [kg]
Fulcrum
Moment load
∆
M [N·m]
mg
Maintenance/inspection
Inspection
It is recommended that periodic inspections would be conducted for the items listed
below after each operation of the motor. If an abnormal condition is noted, discontinue
any use and contact your nearest Oriental Motor sales office.
During inspection
y
Are any of motor mounting screws loose?
y
Are there any abnormal noises in the motor bearings (ball bearings) or other moving
parts?
y
Are there any scratches, signs of stress or loose driver connection in the motor lead
wire?
y
Are there any loose connections on the connector or driver?
y
Are the motor’s output shaft and load shaft out of alignment?
Warranty
Check on the Oriental Motor Website or General Catalog for the product warranty.
Disposal
Dispose the product correctly in accordance with laws and regulations, or instructions of
local governments.
Specifications
Check on the Oriental Motor Website for the product specifications.
General specifications
Degree of protection
IP20
Operation
environment
Ambient
temperature
−10 to +50 °C (+14 to +122 °F) (non-freezing)
Harmonic geared type: 0 to +40 °C (+32 to +104 °F)
(non-freezing)
Humidity
85% or less (non-condensing)
Altitude
Up to 1,000 m (3,300 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water or oil
Storage
environment
Shipping
environment
Ambient
temperature
−20 to +60 °C (−4 to +140 °F) (non-freezing)
Humidity
85% or less (non-condensing)
Altitude
Up to 3,000 m (10,000 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water or oil
Insulation
resistance
100 MΩ or more when 500 VDC megger is applied between the
windings and the case.
Dielectric
strength
Sufficient to withstand the following conditions applied between the
windings and the case for 1 minute.
y
0.5 kVAC 50/60 Hz
Regulations and standards
RoHS Directive
The products do not contain the substances exceeding the restriction values of RoHS
Directive (2011/65/EU).