6 Guidance
If you are new to the
NETC01-M3
, read this section to understand the operating methods along with the
operation flow.
As an example, this chapter explains how to perform positioning operation for the "
CRK
Series
FLEX Built-in controller type [described as the
CRD-KD
in this manual]," using the
NETC01-M3
via
MECHATROLINK-
Ⅲ
communication.
Note
•
Before operating the motor, check the condition of the surrounding area to ensure safety.
•
Refer to "13.8 Parameter mode" on p.57 for how to set parameters.
STEP 1
Set the transmission rate, station address and address number
Using the parameter
1. Set the "connection (address number 0)" parameter of the
NETC01-M3
to "1: Enable."
2.
Cycle the
NETC01-M3
power.
Note
•
“Connection” parameters will be enabled after the power is cycled.
•
When setting the parameters of the
NETC01-M3
, use the
OPX-2A
or
MEXE02
.
Using the switches
•
Setting condition of
CRD-KD
•
Address number of
CRD-KD
: 0
•
Connection device of
CRD-KD
: Network converter
•
Setting condition of
NETC01-M3
•
MECHATROLINK-
Ⅲ
station address: 61h
•
RS-485 transmission rate: 625 kbps
•
Remote I/O occupied size: 16 bit mode
•
Number of transmission bytes: 32 bytes
Connection device:
Network converter
CRD-KD
address
number: 0
×10: 6
×1: 1
NETC01-M3
CRD-KD
SW4: OFF
SW1 to 3: ON
MECHATROLINK-
䊢
station number: 61h
SW2-No.1: OFF
Remote I/O occupied size:
16 bit mode
SW2-No.3: ON
SW2-No.2: OFF
Number of transmission
bytes: 32 bytes
SW1: 7
SW1: 0
RS-485 transmission
rate: 625 kbps