Details of command
25
Explanation of command
Device group
Common command group
Function group
Control command group
Communication type
Asynchronous command
Completion of command
operation
Confirms by the response byte 1=ALM_CLR (=06h) and STATUS.CMDRDY=1.
Note
ALM_CLR_MODE
0: Resets the MECHATROLINK-II communication error that is currently occurred.
9-5
Establish connection command (CONNECT: 0Eh)
This command is used to establish the MECHATROLINK-II communication connection.
Data format
Byte
Command
(Master to
NETC01-M2
)
Response
(
NETC01-M2
to master)
1
CONNECT (0Eh)
CONNECT (0Eh)
2
Reserved (0h)
ALARM
3
STATUS
4
Reserved (0h)
5
VER (21h)
VER (21h)
6
COM_MODE
COM_MODE
7
COM_TIME
COM_TIME
8 to 15
Reserved (0h)
Reserved (0h)
16
WDT
RWDT
17 to 31
Reserved (0h)
Reserved (0h)
Explanation of command
Device group
Common command group
Function group
Network command group
Communication type
Asynchronous command
Completion of command
operation
Confirms by the response byte 1=CONNECT (=0Eh), STATUS.CMDRDY=1, VER,
COM_MODE and COM_TIME.
Note
•
VER: Version number in the application layer
•
COM_MODE: Communication mode
Summary of Contents for NETC01-M2