How to install the fan 

Install the fan onto an appropriate flat metal plate having excellent vibration 
resistance and heat conductivity. 
Drill holes on the mounting plate and fix the fun on the plate using screws. 
For air orientation and rotational direction, see the “  AIRFLOW” and 
“ROTATION  ” indications shown on the fan’s side frame. The direction shown 
by the 

  mark indicates the outlet, while the inlet is in the opposite direction. 

The direction shown by the    mark indicates the direction of rotation. 

 

Model 

Screw size 

Tightening torque 

MRE10/MRE12 

M4 

0.6 N·m (85 oz-in) 

MRE16/MRE18 

M5 

1.2 N·m (170 oz-in) 

Wiring 

 

Connect the cable according to the figure (

 for alarm type only). 

 

• 

MRE10

/

MRE12

 

PE

Power supply
lead wires

Black

Black

 

• 

MRE16

/

MRE18 

Single-phase 

PE

Power supply
cable

Alarm cable

N

L

White
Black

Blue
Orange

 

• 

MRE16

/

MRE18 

Three-phase 

PE

L1 (R)

L2 (S)

L3 (T)

Red

White
Black

Power supply
cable

Alarm cable

Blue
Orange

 

 

Connector pin assignments 

2 poles 

1

2

 

4 poles 

1

3

2

4

 

 

• 

MRE10

/

MRE12 

Single-phase (2 poles) 

• 

MRE16/MRE18 

Single-phase (4 poles) 

Pin No. 

Color 

 

Pin No.

Color 

Connecting 

1 Black   

1 Black 

2 Black   

2 White 

     3 

 None 

     4 

 None 

 

• 

MRE16/MRE18 

Alarm (2 poles) 

• 

MRE16/MRE18 

Three-phase (4 poles) 

Pin No. 

Color 

 

Pin No.

Color 

Connecting 

1 Blue   

1 Red  L1 

(R) 

2 Orange   

2  White  L2 

(S) 

     3 

Black 

L3 

(T) 

     4 

 None 

 

Cable connector housings/contacts 

Manufacturer: Molex 

 

Model No. 

Model 

Housing Contact 

Poles 

Applicable 

lead wire 

MRE10 
MRE12 

Power supply 

5557-02R-210 

Power supply 

5557-04R-210 

5556T 

AWG18 

(0.75 mm

2

)

MRE16 
MRE18 

Alarm 5557-02R-210 

5556GS7F 

AWG20 

(0.5 mm

2

Alarm function 

 

The alarm signal is output when the fan’s rotation speed falls below   
1800±300 r/min. 

 

Note 

The alarm circuit do not have a delay function. Avoiding detection, 
when starting the fan, requires an external delay function. Set the 
delay time to 10 sec. min. 

 

Low-speed alarm, contact alarm type 
(Normal: contact OFF) 

• 

Model 

MRE16- AH

MRE18- AH

 

• 

Alarm specification 

Output format 

Relay output 

Output status 

Normal: contact OFF 
Abnormal: contact ON 

R

0 V

V

0

Vout

I

User's circuit

Fan

Orange

Blue

Maximum 
rating 

Output rating: resistance load 10 VA max. (100 V max./ 0.5 A max.)
Minimum load: 5 V    1 mA 
(Design your alarm circuit to operate at 0.5 mA or less.) 

 

Low-speed alarm, contact alarm type 
(Normal: contact ON) 

• 

Model 

MRE16- BH

MRE18- BH

 

• 

Alarm specification 

Output format 

Relay output 

Output status 

Normal: contact ON 
Abnormal: contact OFF 

R

0 V

V

0

Vout

I

User's circuit

Fan

Orange

Blue

Maximum 
rating 

Output rating: resistance load 10 VA max. (100 V max./ 0.5 A max.)
Minimum load: 5 V    1 mA 
(Design your alarm circuit to operate at 0.5 mA or less.) 

 

Low-speed alarm, electronic alarm type 

• 

Model 

MRE16- MH

MRE18- MH

 

• 

Alarm specification 

Output format 

Open-collector output 

Output status 

Normal: L level 
(internal transistor ON) 
Abnormal: H level 
(internal transistor OFF) 

R

0 V

V

0

User's circuit

Fan

Vout

I

Orange

Blue

 

Maximum 
rating 

Maximum voltage: V out max.=30 VDC 
Leakage current: I=250 µA max. 
Maximum current: I out max.=15 mA 
Output saturated voltage: V out (sat)=0.4 V max. 

∗ 

Enter the voltage 

B

D

 or 

T

 in the box ( ) within the model name. 

Overheat protection 

 

Impedance protection (

MRE10

MRE12

Impedance protection means the fan will not burn out in the event of a lockup. 

 

Thermal protector (

MRE16

MRE18

The fan uses a thermal protector for overheat protection. Once the temperature 
reaches a specified level, the internal thermal protector that has an automatic 
return feature is triggered to stop the fan operation. Be sure to turn off the power 
when checking the thermal protector. 

Operating temperature of thermal protectors 

Open (power OFF): 120±5 °C (248±9 °F) 
Close (power ON): 77±15 °C (170±27 °F) 
 
 
 
 
 
 
 
 

• 

Unauthorized reproduction or copying of all or part of this manual is 
prohibited. 

• 

Oriental Motor shall not be liable whatsoever for any problems relating to 
industrial property rights arising from use of any information, circuit, 
equipment or device provided or referenced in this manual. 

• 

Characteristics, specifications and dimensions are subject to change 
without notice. 

• 

While we make every effort to offer accurate information in the manual, we 
welcome your input. Should you find unclear descriptions, errors or 
omissions, please contact the nearest office. 

• 

 and 

  are registered trademarks or trademarks of 

Oriental Motor Co., Ltd., in Japan and other countries. 

 

© Copyright

 ORIENTAL MOTOR CO., LTD. 2011 

 

Printed on Recycled Paper

•  Please contact your nearest Oriental Motor office for further information.

Headquarters  Tokyo, Japan
Tel:03-6744-0361 Fax:03-5826-2576

Tel:01 47 86 97 50 

Fax:01 47 82 45 16

Tel:(02)8228-0707 Fax:(02)8228-0708

Technical Support  Tel:(800)468-3982
8:30 

A.M.

 to 5:00 

P.M.

, P.S.T. (M-F)

7:30 

A.M.

 to 5:00 

P.M.

, C.S.T. (M-F)

E-mail: [email protected]
www.orientalmotor.com

Headquarters and Düsseldorf Office  Tel:0211-52067-00 

Fax:0211-52067-099

Munich Office                          

Tel:089-3181225-00 

Fax:089-3181225-25

Hamburg Office                         

Tel:040-76910443 

Fax:040-76910445

Tel:01256-347090 Fax:01256-347099

Tel:02-93906346 Fax:02-93906348

Tel:+65-6745-7344 Fax:+65-6745-9405

KOREA
Tel:080-777-2042 Fax:02-2026-5495

Tel:(03)22875778 Fax:(03)22875528

Tel:+66-2-251-1871 Fax:+66-2-251-1872

Tel:400-820-6516 Fax:021-6278-0269