IO data
3 PR
OFINE
46
4-3
Output data
Data transferred from the host controller to the driver is called Output data.
Output data format
Contents of the Output data are as follows. The order of data is in big-endian format.
Byte
Size (byte)
Description
0, 1
2
Remote I/O (R-IN)
2, 3
2
Operation data number selection
4, 5
2
Fixed I/O (IN)
6, 7
2
Direct data operation operation type
8 to 11
4
Direct data operation position
12 to 15
4
Direct data operation operating speed
16 to 19
4
Direct data operation starting/changing rate
20 to 23
4
Direct data operation stopping deceleration
24, 25
2
Direct data operation operating current
26, 27
2
Direct data operation forwarding destination
28, 29
2
Reserved
30, 31
2
Read parameter ID
32, 33
2
Write request
34, 35
2
Write parameter ID
36 to 39
4
Write data
z
Order of 2 byte data
Example: When the direct data operation operating current is set to 1,000 (0x03E8h)
Byte
Size (byte)
Description
Value (Hex)
24
2
Direct data operation operating current (upper)
0x03
25
Direct data operation operating current (lower)
0xE8
z
Order of 4 byte data
Example: When the direct data operation position is set to 300,000 (0x000493E0h)
Byte
Size (byte)
Description
Value (Hex)
8
4
Direct data operation position (most significant)
0x00
9
Direct data operation position (upper)
0x04
10
Direct data operation position (lower)
0x93
11
Direct data operation position (least significant)
0xE0