Connecting the EtherNet/IP cable (CN3, CN4)
Connect the EtherNet/IP cable to the EtherNet/IP connector (CN3, CN4).
Pin assignment
Signal name
Description
TXP
Transmitted data +
TXN
Transmitted data −
RXP
Received data +
N.C.
−
N.C.
−
RXN
Received data −
N.C.
−
N.C.
−
TXP
TXN
RXP
N.C.
N.C.
RXN
N.C.
N.C.
4-4
Connecting the USB cable
Using a USB cable of the following specifications, connect a PC in which the
MEXE02
software has been installed to
the USB connector.
Specifications
USB2.0 (full speed)
Cable
Length: 3 m (9.8 ft.) or less
Shape: A to mini B
•
Connect the driver and a PC directly using a USB cable.
•
In large electrically noisy environments, use the USB cable with a ferrite core or install a ferrite core
to the USB cable.
4-5
Connecting input signals (CN5)
Connect when using direct inputs or sensors.
Applicable lead wire and terminal
Applicable lead wire
•
AWG26 to 20 (0.14 to 0.5 mm
2
)
•
Lead wire strip length: 6 mm (0.24 in.)
Applicable ferrule terminal
Without sleeve: 0.25 to 0.5 mm
2
With sleeve: 0.25 to 0.34 mm
2
Pin assignment
Pin No.
Signal name
Description *
1
IN0+
Control input 0 (STOP)
2
IN0−
3
IN1+
Control input 1 (FREE)
4
IN1−
1
2
3
4
* ( ): Initial value