background image

 

HM-9208-3

 

O P E R A T I N G   M A N U A L

 

Torque Motors

 

   

   

Thank you for purchasing an Oriental Motor product. 
This Operating Manual describes product handling procedures and 
safety precautions. 

• 

Please read it thoroughly to ensure safe operation. 

• 

Always keep the manual where it is readily available. 

 

Introduction 

 

Before using the motor 

Only qualified personnel should work with the product. 
Use the product correctly after thoroughly reading the section “Safety 
precautions”. 
Should you require the inspection or repair of internal parts, contact the 
Oriental Motor office where you purchased the product. 
The product described in this manual has been designed and manufactured 
for use as an internal component for general industrial equipment, and must 
not be used for any other purpose. Oriental Motor Co., Ltd. is not responsible 
for any damage caused through failure to observe this warning. 
If you have purchased a torque motor and power controller package, also 
refer to the operating manual for Power Controller 

TMP-1

 

Standard and CE Marking 

Motors are recognized by UL and certified by CQC. Recognized name and 
certified name are motor model name. 
Voluntary display of the CE mark conforming to the Low Voltage Directives. 

Standards 

UL 1004, UL 2111, CSA C22.2 No.100, CSA C22.2 No.77, GB 12350 

Standards File No. 

UL File No.E64197, CQC 

Applications for Standard 

EN 60034-1, EN 60034-5, EN 60664-1, EN 60950-1 
A Running Heating Test and a Locked-Rotor Test has been conducted with a 
aluminum radiation plate of size indicated below. For the motor with a 
gearhead, tests has been conducted with a gearhead instead of the radiation 
plate. 

 

First number 

in motor 

name 

Size [mm (in.)] 

Thickness 

[mm (in.)] 

Material

115 × 115 (4.53 × 4.53) 

125 × 125 (4.92 × 4.92) 

135 × 135 (5.31 × 5.31) 

165 × 165 (6.50 × 6.50) 

5 (0.20) 

Aluminum

Installation conditions 

Overvoltage category II, Pollution degree 2, Class I equipment (For EN/IEC 
Standards) 
When the machinery to which the motor is mounted requires overvoltage 
category III and pollution degree 3 specifications, install the motor in a 
cabinet that comply with IP54 and connect to power supply via an isolation 
transformer. 

Standards for accessories 

Capacitor:  UL File No.E83671 (CYWT2), VDE License Nos.112847   

(capacitors with a rated voltage of 250 VAC), 114747 (capacitors 
with a rated voltage of 450 VAC) 

Capacitor cap: UL File No.E56078 (YDTU2) 

 

Hazardous substances 

RoHS (Directive  2002/95/EC  27Jan.2003) compliant 

 

Safety precautions 

The precautions described below are intended to prevent danger or injury to 
the user and other personnel through safe, correct use of the product. Use the 
product only after carefully reading and fully understanding these 
instructions. 

 

Warning

Handling the product without observing the 
instructions that accompany a “Warning” symbol 
may result in serious injury or death. 

Caution

Handling the product without observing the 
instructions that accompany a “Caution” symbol 
may result in injury or property damage. 

Note

Note

 

The items under this heading contain important 
handling instructions that the user should observe 
to ensure safe use of the product. 

 

Warning

 

• 

Do not use the product in explosive or corrosive environments, in the 
presence of flammable gases, locations subjected to splashing water, or 
near combustibles. Doing so may result in fire, electric shock or injury. 

• 

Assign qualified personnel the task of installing, wiring, 
operating/controlling, inspecting and troubleshooting the product. Failure 
to do so may result in fire, electric shock or injury. 

• 

Do not transport, install the product, perform connections or inspections 
when the power is on. Always turn the power off before carrying out these 
operations. Failure to do so may result in electric shock. 

• 

Turn off the power in the event the overheat protection device (thermal 
protector) is triggered. Failure to do so may result in injury or damage to 
equipment, since the motor will start abruptly when the overheat 
protection device (thermal protector) is automatically reset. 

• 

To prevent the risk of electric shock, use the motor for   
class I equipment only.

 

Motore zur Verwendung in Geräten der Schutzklasse I.

 

• 

Install the motor in an enclosure in order to prevent electric shock or 
injury. 

• 

Install the motor so as to avoid contact with hands, or ground it to prevent 
the risk of electric shock.

 

Die Gehäuse der Motore sind mit einer Schraube und Zahnscheibe sicher 
mit dem geerdeten Gehäuse des Gerätes zu verbinden.

.

 

• 

Keep the input-power voltage within the specification to avoid fire and 
electric shock. 

• 

Connect the cables securely according to the wiring diagram in order to 
prevent fire and electric shock. 

• 

Do not forcibly bend, pull or pinch the lead wires. Doing so may result in 
fire and electric shock. 

• 

Be sure to insulate the connection terminal of the capacitor. Failure to do 
so may result in electric shock. 

• 

Turn off the power in the event of a power failure, or the motor will 
suddenly start when the power is restored and may cause injury or damage 
to equipment. 

• 

Do not touch the connection terminal of the capacitor immediately after 
the power is turned off (for a period of 30 seconds). The residual voltage 
may cause electric shock. 

• 

Do not disassemble or modify the motor. This may cause electric shock or 
injury. 

 

Caution

 

• 

Do not use the motor beyond its specifications, or electric shock, injury or 
damage to equipment may result. 

• 

Do not touch the motor during operation or immediately after stopping. 
The surface is hot and may cause a skin burn(s). 

• 

Do not hold the motor output shaft or motor lead wires. This may cause 
injury. 

• 

Keep the area around the motor free of combustible materials in order to 
prevent fire or a skin burn(s). 

• 

To prevent the risk of damage to equipment, leave nothing around the 
motor that would obstruct ventilation. 

• 

To prevent bodily injury, do not touch the rotating parts (output shaft) of 
the motor during operation. 

Summary of Contents for 2TK3A-AW2J

Page 1: ...7 GB 12350 UL File No E64197 CQC EN 60034 1 EN 60034 5 EN 60664 1 EN 60950 1 1 mm mm 2 115 115 3 125 125 4 135 135 5 165 165 5 2 EN IEC 3 IP54 UL File No E83671 CYWT2 VDE License No 112847 250 VAC 114...

Page 2: ...K20GN AW2 CH140CFAUL2 5TK20GN CW2J 5TK20GN CW2 CH45BFAUL 5TK20GN CW2E 5TK20GN CW2 CH40BFAUL 5GN S 2TK3A AW2J 2TK3A AW2 CH70CFAUL2 2TK3A AW2U 2TK3A AW2 CH60CFAUL2 2TK3A CW2J 2TK3A CW2 CH18BFAUL 2TK3A C...

Page 3: ...3 h7 2GN M4 4 3 mm 1 N m 10 cm 90 1 2 2 90 2 4 TMP 1 B 90 C 90 C 3 18 2GN S 3GN S 4GN S 5GN S 50 180 25 36 CW CCW L N PE CW L N PE CCW 4 A B C D 2 187 Tyco Electronics AMP 187 A B C D 1 1...

Page 4: ...200 V 5 200 V 100 V 220 230 V 5 220 230 V 115 V 5 5 TP 3 W 130 5 C 90 15 C 6 20 W 130 5 C 82 15 C 3 90 C Copyright ORIENTAL MOTOR CO LTD 2008 http www orientalmotor co jp PHS 9 00 18 30 9 00 17 30 TEL...

Page 5: ...dling the product without observing the instructions that accompany a Caution symbol may result in injury or property damage Note Note The items under this heading contain important handling instructi...

Page 6: ...4TK10A AW2 CH110CFAUL2 4TK10A CW2J 4TK10A CW2 CH35BFAUL 4TK10A CW2E 4TK10A CW2 CH30BFAUL 5TK20A AW2J 5TK20A AW2 CH180CFAUL2 5TK20A AW2U 5TK20A AW2 CH140CFAUL2 5TK20A CW2J 5TK20A CW2 CH45BFAUL 5TK20A...

Page 7: ...cket head screws used to assemble the motor and gearhead together only tentatively secure the two components Always use the four supplied mounting screws when installing the motor gearhead assembly Co...

Page 8: ...blocks or crimp terminals are used check them for poor connection Phenomena Check items The motor rotates in the direction opposite to the specified direction Connect correctly by referring to Wiring...

Page 9: ...350 UL File No E64197 CQC EN 60034 1 EN 60034 5 EN 60664 1 EN 60950 1 1 mm mm 2 115 115 3 125 125 4 135 135 5 165 165 5 2 EN IEC 3 IP54 UL File No E83671 CYWT2 VDE License No 112847 250 VAC 114747 450...

Page 10: ...AW2 CH140CFAUL2 5TK20GN CW2J 5TK20GN CW2 CH45BFAUL 5TK20GN CW2E 5TK20GN CW2 CH40BFAUL 5GN S 2TK3A AW2J 2TK3A AW2 CH70CFAUL2 2TK3A AW2U 2TK3A AW2 CH60CFAUL2 2TK3A CW2J 2TK3A CW2 CH18BFAUL 2TK3A CW2E 2T...

Page 11: ...2GN M4 1 N m 10 cm 90 1 2 2 90 2 4 TMP 1 B 90 C 90 C 3 18 2GN S 3GN S 4GN S 5GN S 50 180 25 36 CW CCW L N PE CW L N PE CCW 4 A B C D 2 Tyco Electronics AMP AMP FASTON Terminal 187 187 A B C D 1 1 4 3...

Page 12: ...W 130 5 C 90 15 C 6 20 W 130 5 C 82 15 C 3 90 C Copyright ORIENTAL MOTOR CO LTD 2008 Tel 6745 7344 Fax 6745 9405 KOREA Tel 032 822 2042 3 Fax 032 819 8745 Tel 03 22875778 Fax 03 22875528 Headquarters...