4
Technical Information
Model:
FSCD400IM
Electrical rating:
115VAC ~ 60Hz ~ 2.2A
Power consumption:
0.80kWh/24h
High/Low side pressure:
261psi/65psi
Refrigerant:
R134a, 3.88 oz
Ice making capability:
3½ - 4 lbs/24h*
Ice shape:
Crescent
Unit width x depth x height:
18” x 20¼” x 45¼”
Unit weight:
92.6 lbs
Minimum installation clearance:
4” from top, back and sides
Optimum temp. range for feed water:
41ºF to 90ºF
*
The ac tual quantity of ice produced per day can vary with room and water conditions.
Energy-Saving Tips
•
Do not place your refrigerator next to a heating vent, a range or in direct
sunlight.
•
Keep the doors closed as much as possible, especially in hot, humid
weather.
•
Defrost the freezer compartment whenever frost becomes
1
inch thick.
•
Cover foods to reduce moisture buildup inside the refrigerator.
Water Connection
The ice maker in the freezer compartment must be connected to a continuous
water supply with a minimum pressure of 15 psig and a static pressure not to
exceed 80 psig. A cold water inlet of 1/4” soft copper tubing with a shut-off
valve is required. A 1/4” FPT (Female Pipe Thread) fitting will make the
connection to the short inlet tube at the back of the refrigerator. The
temperature of the water feeding into the ice maker should be between 41ºF
and 90ºF for proper operation.
In general, it is always a good idea to use a water filter. A water filter, if it is of
the proper type, can remove taste and odors as well as particles. Some water
3
Summary of Contents for FSCD400IM