background image

4

EN

To insert batteries:

1

2

1.  Unscrew  the  anemometer  from  the  wind  sensor 

carefully.

2.  Insert  batteries  matching  the  polarities  (+  /  -)  and 

replace the anemometer. Press 

RESET

 after each 

battery change.

SET UP REMOTE TEMPERATURE / HUMIDITY

SENSOR

The remote sensor can collect data from up to 3 channels.

To set up the remote sensor:

1.  Slide open the battery door.
2.  Slide  channel  switch  to  select  a  channel  (1,  2,  3).   

Ensure you use a different channel for each sensor.

3.  Insert the batteries, matching the polarities (+ / -).
4.  Press

 RESET

 after each battery change.

5.  Close the battery door.

SET UP RAIN GAUGE

The rain gauge collects rain and takes rainfall readings. 
The  sensor  can  remotely  transmit  data  to  the  base 
station.

To set up the rain gauge:

1.  Remove screws and slide the cover off in an upwards 

motion. 

2.  Insert the batteries (2 x UM-3 / AA), matching the polarities 

(+ / -).  Press 

RESET

 after each battery change.

3.  Remove the fibre tape. 

SET UP BASE STATION

 NOTE  

Install batteries in the remote sensors before the 

base station matching the polarities (+ and -).

For continuous use, please install the AC adaptor.  The 
batteries are for back-up use only.

 NOTE 

  Make sure the adaptor is not obstructed and is 

easily accessible to the unit.

  NOTE 

  The  base  station  and  adaptor  should  not  be 

exposed to wet conditions.  No objects filled with liquid, 
such  as  vases,  should  be  placed  on  the  base  station 
and adaptor.

To  completely  disconnect  from  power,  unplug  adaptor 
from the mains.

To insert batteries:

E

U

/U

1.  Slide open the battery door.
2.  Insert the batteries, matching the polarities (+ / -).
3.  Press

 RESET

 after each battery change.

4.  Close the battery door.

  NOTE 

 

Do  not  use  rechargeable  batteries.  It  is 

recommended that you use alkaline batteries with this 
product for longer performance.

 NOTE 

 Batteries should not be exposed to excessive 

heat such as sunshine or fire.

The  battery  icon  indicator 

  may  appear  in  the 

following areas: 

AREA

MEANING

Weather Forecast 
Area

Battery in the base station is 
low. 

 will show when AC 

adaptor is disconnected.

Temperature or 
Humidity Area

The displayed channel 
indicates the outdoor sensor 
for which battery is low.

Wind Speed / Wind 
Direction / Wind Chil 
Area

Battery in the wind sensor 
is low.

UVI / Barometer / 
Rainfall Area

Battery in the UV / Rain 
sensor is low.

VERIFY CONNECTION

Before proceeding to install sensors outside, please verify 
communication to the base station.

Summary of Contents for WMR88

Page 1: ...ndex 8 Barometer 8 Rainfall 9 Upload data to PC software 9 Backlight 9 Reset 9 Speci cations 9 Precautions 10 About Oregon Scienti c 10 EU declaration of conformity 10 FCC statement 11 INTRODUCTION Th...

Page 2: ...W EU UK 1 2 3 4 5 6 7 2 x AA UM 3 1 5V batteries 4 x screws Type B 1 x rain collector 1 Wall mount holes 2 Battery compartment 3 SEARCH Searches for sensors or for the radio controlled clock signal 4...

Page 3: ...ator 5 Time date calendar 6 Moon phase WIND SENSOR 1 2 3 4 1 Wind direction 2 Wind vane casing 3 Anemometer 4 Solar power socket RAIN GAUGE Base and funnel 1 2 3 1 Rain gauge 2 Battery compartment 3 R...

Page 4: ...ptor The batteries are for back up use only NOTE Make sure the adaptor is not obstructed and is easily accessible to the unit NOTE The base station and adaptor should not be exposed to wet conditions...

Page 5: ...Secure the sensor connector in the desired location a Align the back of the sensor connector to an existing pole Secure in place by inserting the ends of the U bolt into the holes on the sensor conne...

Page 6: ...appears when it is enabled NOTE For best reception the base station should be placed on a at non metallic surface near a window in an upper oor of your home The antenna should be placed away from elec...

Page 7: ...t unit Press UNIT to select C F NOTE The unit of all temperature related displays will be changed simultaneously To view temperature Current Max Min temperature readings 1 Press SELECT to navigate to...

Page 8: ...recorded from 9 to 10 pm and 6 shows the reading recorded earlier in the evening between 4pm 5pm To view the UV Barometer Rainfall readings 1 Press SELECT to navigate to the UV Barometer Rainfall Area...

Page 9: ...om http www2 os weather com help Click on PC Software Manual BACKLIGHT Press LIGHT to activate the backlight for 5 seconds RESET Press RESET to return to the default settings SPECIFICATIONS BASE STATI...

Page 10: ...s product on certain types of wood may result in damage to its nish for which Oregon Scienti c will not be responsible Consult the furniture manufacturer s care instructions for information The conten...

Page 11: ...determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase t...

Reviews: