Oregon Scientific RMS 300 User Manual Download Page 4

E

N

4

NOTE

 Use alkaline batteries for longer usage and consumer 

grade lithium batteries in temperatures below freezing.

SENSOR DATA TRANSMISSION

To search for a sensor: 

Press and hold 

 

+ MODE

.

The  remote  sensor  reception  icon  will  show  the  following 
status:

ICON

DESCRIPTION

Main unit is searching for sensor(s).

A channel has been found.

The sensor cannot be found. 

TIP

 

The transmission range may vary depending on many 

factors. You may need to experiment with various locations 
to get the best results.

CLOCK 

CLOCK RECEPTION

This  product  is  designed  to  synchronize  its  clock 
automatically with a clock signal.

RMS300:

Slide 

EU / UK

 to select the signal received.

• 

EU:  DCF-77  signal:  within  1500  km  (932  miles)  of 
Frankfurt, Germany.

• 

UK:  MSF-60  signal:  within  1500  km  (932  miles)  of 
Anthorn, England.

RMS300A:

WWVB-60  signal:  within  3200  km  (2000  miles)  of  Fort 
Collins, Colorado.

To enable / disable clock signal reception:

Press  and  hold 

 

to  enable  or 

 

to  disable  clock 

signal reception.

NOTE

 

Reception takes 2-10 minutes. If the signal is weak, 

it  can  take  up  to  24  hours  to  get  a  valid  signal.

 

If  signal 

reception is unsuccessful, place your unit next to a window, 
press and hold 

 

to force another signal search.

 

Clock signal reception indicator: 

STRONG 

SIGNAL

WEAK SIGNAL

NO SIGNAL

RMS300 IM EN R3.indd   4

1/4/08   11:52:35 AM

Summary of Contents for RMS 300

Page 1: ...ert Batteries 3 Remote Sensor 3 Sensor Data Transmission 4 Clock 4 Clock Reception 4 Manually Set Clock 4 Temperature And Humidity 5 Ice Alert Channel 1 Only 5 Connection to PC 5 Backlight 6 Reset 6 S...

Page 2: ...e 4 Outdoor humidity 5 Indoor temperature and humidity 6 Clock signal reception indicator 7 Main unit battery indicator 8 Clock calendar display 9 USB status indicator 10 Time zone RMS300A only 11 Ice...

Page 3: ...dicator 2 Wall mount hole 3 Battery compartment 4 RESET hole 5 CHANNEL switch GETTING STARTED INSERT BATTERIES 1 Remove the battery compartment 2 Insert the batteries matching the polarities see FIG 2...

Page 4: ...o synchronize its clock automatically with a clock signal RMS300 Slide EU UK to select the signal received EU DCF 77 signal within 1500 km 932 miles of Frankfurt Germany UK MSF 60 signal within 1500 k...

Page 5: ...F To auto scan channels Press and hold MEM to display each channel s recorded data in sequence for 3 seconds To select channel press To toggle between current minimum and maximum temperature humidity...

Page 6: ...idity range 25 95 Humidity resolution 1 Power 2 x UM 3 AA 1 5 V batteries REMOTE UNIT THGN132N L x W x H 50 x 22 x 96 mm 1 9 x 0 9 x 3 8 in Weight 62 g 2 2 ounces without battery Signal frequency 433...

Page 7: ...c products If you re in the US and would like to contact our Customer Care department directly please visit www2 oregonscienti c com service support OR Call 1 800 853 8883 For international inquiries...

Page 8: ...ceiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help DECLARATION OF CONFORM...

Reviews: