background image

7

GB

Power

Main  unit

: 2 pcs UM-3 or “AA” 1.5V
battery

Remote  sensing  unit

: 2 pcs UM-3 or “AA” 1.5V

alkaline battery

Weight

Main  unit

: 6.10 ounces (173 gm)

Remote  sensing  unit

: 9.17 ounces (260 gm)

Dimensions

Main unit

: 5.24 x 3.54 x 0.98 inches

(133 x 90 x 25mm)

Remote sensing unit

: Dia 5.51x5.71 inches

(140 x 145mm)

NOTE ON COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must
accept any interference received, including interference that
may cause undesired operations.

Warning:   Changes or modifications to this unit not
expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.

FCC  :

NOTE:  This equipment has been tested and found to comply
with the limits for a Class  B digital device, pursuant to Part
15 of the FCC Rules.  These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications.

However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by
one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected.

- Consult the dealer of an experienced radio/TV technician

Summary of Contents for RGR122

Page 1: ...n guage is equipped with the following functions Daily and total rainfall display Nine day rainfall history Rainfall alarm Indoor temperature display Maximum and minimum temperatures Real time calendar clock Daily alarm 300 feet transmission range The RGR122 operates at 433MHz No wire installation is required MAIN FEATURES MAIN UNIT ...

Page 2: ...old to clear the temperature memory in normal mode Decreases a value in setting mode F RAIN HIST BUTTON Displays the rainfall history in normal mode Increases a value in setting mode G RAIN ALARM BUTTON Displays the rain alarm setting Presses and hold to enter the rain alarm setting mode H ANTENNA Receives radio signal from rain collector I C F SWITCH Selects between degree Centigrade C and Fahren...

Page 3: ...he main unit and rain collector within effective range 300 feet 2 a Insert batteries into the rain collector b Mount the rain collector on a level surface c Put drops of water on the cross at the base to check the leveling d Use the metal ring to adjust the leveling of the rain collector 4 3 TOPVIEW Water stay at position 1 4 meansthegauge is not leveled AA UM3 1 5V AA UM3 1 5 V METAL RING ...

Page 4: ...ay Use the IN MM switch to select between inch and millimeter Todisplaythecommencingdateoftherecord press RAINRESET SINCE once Thedatewillappearonthebottomlineofthedisplay To clear the record hold RAIN RESET SINCE for two seconds Note that this will also clear the current Day 0 rainfall RAINFALL HISTORY The rainfall history is displayed on the second line of the LCD display The main unit can recor...

Page 5: ...F switch to select between degree Centigrade and Fahrenheit Use TEMP MEM to display the maximum and minimum temperatures in record The reading will go from maximum to minimum to current and back To clear the memory press and hold TEMP MEM for two seconds CALENDAR CLOCK The calendar clock is displayed on the bottom line of the display Use MODE to change among the clock calendar and daily alarm To s...

Page 6: ...he unit s internal components Doing so will invalidate the warranty on the unit and may cause unnecessary damage The unit contains no user serviceable parts 5 Only use fresh batteries as specified in the user s manual Do not mix new and old batteries as the old ones may leak 6 Always read the user s manual thoroughly before operating the unit SPECIFICATIONS Main unit Display rainfall range total 0...

Page 7: ...nd to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communicatio...

Page 8: ...e possible contact our customer care department for assistance and a return material authorization No returns may be made without a return authorization Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased This warranty does not cover product subjected to abuse misuse accidental damage or tampering CAUTION The content of this manual is subject t...

Page 9: ...oi Bedienungsanleitung Manuale di Istruzioni Instrucciones de Funcionamiento MODEL RGR122 REMOTE RAIN GAUGE for help Company Name Oregon Scientific Inc Address 19861 SW 95th Place Tualatin Oregon 97062 USA Telephone Number 1 800 853 8883 ...

Reviews: