WEATHER FORECAST

This product forecasts the next 12 to 24 hours of
weather within a 30 to 50 km (19 - 31 mile) radius with
70 to 75 percent accuracy. The weather forecast is
always displayed.

VIEW THE LAST 24 HOURS

Press 

SELECT

 2 times until the Barometer Area

flashes. Then, press 

UP

 or 

DOWN

 to view the last

24 hours history.

SET UNIT AND ALTITUDE

You can set the unit of measurement (mb/hPa or inHg)
and altitude. Setting the altitude allows the product to
take more accurate barometric measurements.

1.

Press 

SELECT

 2 times until the Barometer Area

flashes.

2.

Press and hold 

SELECT

 for 2 seconds.

3.

Select altitude (-100 meters to 2500 meters in
increments of 10) and the unit of measurement
(mb/hPa or inHg). Press 

UP

 or 

DOWN

 to

change the setting. Press 

SELECT

 to confirm.

Clear

Partly Cloudy

Cloudy

Rainy

PS M03 English R18

7/16/03, 1:04 PM

14

Summary of Contents for PS-M03

Page 1: ...Full Weather Station with Radio Controlled Clock and AM FM Radio Model PS M03 PS M03U User Manual PS M03 English Cover 6 30 03 11 11 PM 1...

Page 2: ...tween modes 8 Change settings 9 Remote unit setup 9 Clock 10 Alarm 11 Calendar 12 Moon phase 13 Barometer 13 Weather forecast 14 Temperature humidity 15 Radio 17 Backlight 19 Reset system 20 Safety an...

Page 3: ...ireless outdoor temperature and humidity monitoring weather forecasting and digital tuned AM FM radio into a single tool you can use from the convenience of your home Keep this manual handy as you use...

Page 4: ...EN 3 PRODUCT OVERVIEW TOP AND BATTERY COMPARTMENT VIEW DESCRIPTIONS 1 Snooze Light button 12 19 2 Light sensor 19 2 1 PS M03 English R18 7 16 03 1 04 PM 3...

Page 5: ...ment 8 2 Backlight switch 19 3 Reset button 8 20 4 Light sensitivity knob 19 5 Headphone jack 18 6 DC input jack 8 7 Antenna 17 AC power adapter not shown NOTE RESET SENSOR ON LIGHT OFF AUTO LIGHT DC...

Page 6: ...ESCRIPTIONS 1 Low battery icon 8 2 Clock 10 3 Barometer 13 4 Weather forecast 14 5 Moon phase 13 6 Calendar 12 7 Temperature and humidity 15 8 Alarm 11 9 Radio 17 1 2 3 4 5 6 7 8 9 PS M03 English R18...

Page 7: ...0 3 Down decrease setting deactivate auto synch 10 4 Alarm activate deactivate alarm 12 5 Channel switch remote unit 15 6 Radio turn radio or radio alarm on off 12 17 7 Station select a preset station...

Page 8: ...ay 15 17 2 Low battery icon 8 3 Humidity Trend Comfort Level display 15 16 17 4 C F switch 9 5 Channel switch 9 6 Reset button 8 20 7 Battery compartment 8 8 Wall mount hole 9 Battery compartment lid...

Page 9: ...blunt object such as a ball point pen Insert the batteries in the remote unit before you set up the main unit Do not use rechargeable batteries AC POWER ADAPTER An AC power adapter is supplied for use...

Page 10: ...than one remote unit be sure to select a different channel number for each unit INSTALLATION Mount the remote unit on a flat surface using the recess hole on the back of the unit For best results Bef...

Page 11: ...nutes to complete Once complete the icon will stop blinking For best results place the unit away from metal or electrical objects and near a window with a clear view to the sky TO DISABLE OR ENABLE AU...

Page 12: ...louder It shuts off after two minutes The LCD display lights up for the first 8 seconds The Radio alarm turns on the Radio automatically It will turn off after 2 hours SET ALARM 1 Press SELECT several...

Page 13: ...any other button to turn the melody alarm off To turn the alarm off completely deactivate it for the next day press ALARM CALENDAR SET DATE Clock auto synchronization must be deactivated before you ma...

Page 14: ...s over the past 24 hours to provide the weather forecast 14 and a trend line showing the direction of barometric change Barometric changes are measured by the main indoor unit BAROMETRIC TREND The bar...

Page 15: ...history SET UNIT AND ALTITUDE You can set the unit of measurement mb hPa or inHg and altitude Setting the altitude allows the product to take more accurate barometric measurements 1 Press SELECT 2 ti...

Page 16: ...o change channels or Auto scan If you select Auto the channel will change every 3 seconds To deactivate press and hold CHANNEL for 2 seconds again TEMPERATURE AND HUMIDITY With the press of a button y...

Page 17: ...home security systems can cause temporary reception failures between the indoor and outdoor units This is normal and does not affect the general performance of the product Reception will automaticall...

Page 18: ...dcasts with this product ANTENNA The antenna wire is located on the side of the unit Position it for the best reception TURN THE RADIO ON OR OFF Press the RADIO button TRENDS The trend arrow for the l...

Page 19: ...to auto scan The scanning will stop when an available frequency is found STORE STATION TO MEMORY Press STATION for 2 seconds The assigned number 1 8 will show in the Radio Area SLEEP TIMER Press SLEEP...

Page 20: ...CKLIGHT The AC power adapter must be plugged in to use this feature 8 1 The BACKLIGHT switch is located in the battery compartment Move it to the ON position to enable the continuous backlight Move it...

Page 21: ...ratch the LCD display RESET SYSTEM The RESET buttons are located in the battery compartments for the main and remote units Press these buttons with the tip of a blunt object such as a ball point pen w...

Page 22: ...o change without notice Images not drawn to scale TROUBLESHOOTING Check here before contacting our customer service department Baro Strange reading Set altitude unit 14 Backlight No continuous backlig...

Page 23: ...isable auto synchronization 10 Cannot change clock Adjust the antenna 17 Problem Symptom Remedy Clock Cannot auto synchronize 1 Remove batteries 2 Press RESET All memory items will return to default 3...

Page 24: ...r is working 15 SPECIFICATIONS Dimensions L x W x H 129 x 43 x 133 3 mm 5 1 x 1 7 x 5 3 inches Weight 525 grams with batteries Remote unit dimensions L x W x H 75 x 35 x 78 3 mm 3 x 1 4 x 3 1 in Weigh...

Page 25: ...unit RF frequency 433 MHz Range 30 meters 98 feet with no obstructions Transmission approximately every 40 seconds Remote Unit 20 C to 60 C 4 F to 140 F Resolution 0 1 C 0 2 F Comfort 20 C to 25 C 68...

Page 26: ...y Snooze 8 minutes melody only Radio Type Digital tuning PLL Phase Lock Loop stereo Band 531 to 1602 kHz AM 87 5 to 108 0 MHz FM Stations 8 AM 8 FM Volume 8 levels 0 7 Sleep timer 120 minutes in incre...

Page 27: ...our new product and other Oregon Scientific products such as digital cameras hand held organizers health and fitness gear and weather stations The website also includes contact information for our cus...

Page 28: ...f the R TTE Directive applied standard s ETSI EN 301 489 1 3 Ver 1 4 1 2002 08 Safety of information technology equipment Article 3 1 a of the R TTE directive applied standard s EN 60950 2000 Addition...