background image

5

EN

SENSOR DATA TRANSMISSION

Data is sent from the sensor(s) every 60 seconds. The reception icon shown
indicates the status.

SEARCH FOR SENSOR

To search for the sensor, simultaneously press and hold 

MEMORY

 and 

CHANNEL

for 2 seconds.

NOTE

 If the sensor is still not found, please check the batteries.

CLOCK AND CALENDAR

This product tracks the time and date based on radio-controlled signals from the
RTGR328N remote sensor, or manual settings that you enter.

RADIO-CONTROLLED CLOCK

The time and date are automatically updated by radio-controlled clock signals
from official time-keeping organizations in Frankfurt (Germany) and Rugby
(England) unless you disable this feature.

Initial reception takes 2-10 minutes and is initiated when you first set up the unit
or whenever you press 

RESET

. Once complete, the reception icon will stop

blinking.

How these signals work together:

NOTE

  To force a manual search for RF clock reception, press and hold 

SEARCH

on the sensor for 2 seconds.

TURN RADIO-CONTROLLED CLOCK ON / OFF

If you wish to manually set the clock, you must first disable the radio-controlled
feature.

To disable the radio-controlled feature, press and hold 

DOWN

 on the main unit

for 2 seconds.

To enable the radio-controlled feature, press and hold 

UP

 for 2 seconds.

NOTE

  When the feature is disabled, the house icon disappears in the upper left-

hand corner of the VFD display.

SET CLOCK

You only need to do this if you have disabled the radio-controlled clock (or if you
are too far from a RF signal).

1. Press and hold 

CLOCK

 for 2 seconds.

2. Select the time zone offset hour (+ / -23 hours), 12 / 24-hour format, hour,

minute, year, date / month format, month, day and display language.

3. Press 

UP

 or 

DOWN

 to change the setting.

4. Press 

CLOCK

 to confirm.

NOTE

  The language options are (E) English, (F) French, (D) German, (I) Italian,

and (S) Spanish. The language you select determines the weekday display.

SWITCH CLOCK DISPLAY

Press 

CLOCK

 to toggle between:

Clock with day

Clock with time-zone offset

ALARMS

This product has 2 alarms.

SET ALARM

1. Select Alarm#1 or Alarm#2 by pressing 

ALARM

 once or twice (once to view

Alarm #1, twice to view Alarm#2). The alarm number will show just to the right
of the displayed alarm time.

2. Press and hold 

ALARM

 for 2 seconds.

3. Select the hour and minute. Press 

UP

 or 

DOWN

 to change settings.

4. Press 

ALARM

 to confirm.

The Daily Alarm icon   will light up when the alarm is set.

ACTIVATE/ DEACTIVATE ALARM

To activate / deactivate the alarm, press 

ALARM ON / OFF

. The alarm icons will

light up when the alarm is set. You can set Alarm#1, Alarm#2 or both alarms
simultaneously.

NOTE

 When the alarm time is reached, the crescendo alarm will sound for 2

minutes. Press any key to silence the alarm. It will sound at the same time the next
day.

SNOOZE

Tap on the 

SNOOZE / ACTIVATE

 panel to temporarily disable the alarm for 8

minutes.

NOTE

  The alarm icon will blink while Snooze is on.

ICON

DESCRIPTION

Main unit is searching for sensors.

At least 1 channel has been found.

Sensor 1 is sending data. (The number shows which
sensor is selected).

---

The selected sensor cannot be found. Search for the
sensor or check batteries.

ICON

MEANING

The unit has contact with the sensor and has synchronized
the time.

The unit has contact with the sensor but the time has not
been synchronized.

The unit has lost contact with the remote sensor but the
time is synchronized.

The unit has lost contact with the remote sensor and the
time is not synchronized.

The unit cannot reach the remote sensor.

MR238(EN)A4f

9/9/04, 12:11 PM

5

Summary of Contents for Mirror Weather Station MR238

Page 1: ...ines 6 Comfort Zone 6 Reset System 6 Safety and Care 6 Warnings 6 Troubleshooting 6 Specifications 7 About Oregon Scientific 7 EC Declaration of Conformity 7 INTRODUCTION Thank you for selecting the O...

Page 2: ...mperature and humidity readings 11 ALARM button view alarm status set alarm 1 Stand 2 C F button 3 RESET button 4 AC adaptor hole 5 VFD control switch Display On Auto Off You can adjust the angle of t...

Page 3: ...2 Channel number 3 Low battery icon 4 Time 5 Temperature C or F 6 Humidity 7 Temperature Humidity 1 2 3 REMOTE SENSOR BACK VIEW 1 Wall mount 2 CHANNEL switch 1 5 3 RESET 4 C F switch 5 SEARCH 6 EU UK...

Page 4: ...results Insert the batteries and select the unit channel and radio signal format before you mount the sensor Place the sensor out of direct sunlight and moisture Do not place the sensor more than 30 m...

Page 5: ...nth day and display language 3 Press UP or DOWN to change the setting 4 Press CLOCK to confirm NOTE The language options are E English F French D German I Italian and S Spanish The language you select...

Page 6: ...ather within a 30 50 km 19 31 mile radius The forecast is based on barometric pressure trend readings The top area shows an animated icon indicating the forecasted weather WEATHER FORECAST ICONS NOTE...

Page 7: ...BOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about Oregon Scientific products such as digital cameras MP3 players children s electronic learning products and games p...

Page 8: ...EN 8 2004 Oregon Scientific All rights reserved P N 086 003642 019 MR238 EN A4f 9 9 04 12 11 PM 8...

Page 9: ...9 EN Mirror Weather Station Model MR238 User Manual MR238 EN A4f 9 9 04 12 11 PM 9...

Reviews: