background image

3

GB

LCD display symbols

Symbol

Description

      Explanation

Systolic pressure

Diastolic pressure

Time

The current time.

(hour : minutes)

Mean arterial

The average blood pressure

pressure

measured (for more information,

see page 4, “What is Mean
Arterial Pressure?”).

Pulse

Pulse rate per minute.

Memory

If “MEM” shows, the displayed

measurement value is from the
memory, and not necessarily from
the last reading.

Weak battery

Batteries are low and need to be
replaced.

Inflating

Unit is inflating with air to obtain
the needed level of pressure.

Deflating

Wrist cuff air is exhausting, or
deflating.

SAFETY AND CARE INSTRUCTIONS

Safety precautions

Please observe the following safety precautions when setting
up and using your blood pressure monitor.

·

This device is intended for adult use only.

·

This device is intended for non-invasive measuring and
monitoring of arterial blood pressure. It is not intended for
use on extremities other than the wrist or for functions
other than obtaining a blood pressure measurement.

·

Do not confuse self-monitoring with self-diagnosis. This
unit allows you to monitor your blood pressure. Do not
begin or  end medical treatment based solely on the
measurements of this device. Consult a physician for
treatment advice.

·

If you are taking medication, consult your physician to
determine the most appropriate time to measure your blood
pressure. Never change a prescribed medication without
consulting your physician.

·

This unit is not suitable for continuous monitoring during
medical emergencies or operations.

·

If the cuff pressure exceeds 300mmHg, the unit will
automatically deflate. Should the cuff not deflate when
pressures exceeds 300mmHg, detach the cuff from the
wrist and press the ON button to stop inflation.

·

To avoid measurement errors, carefully read this manual
before using the product.

The highest blood pressure
measured.

The lowest blood pressure
measured.

Summary of Contents for BPW211

Page 1: ...lic pressure 4 What is mean arterial pressure MAP 4 Why measure your blood pressure 4 What is the standard blood pressure classification 5 Variation in blood pressure 5 How does the blood pressure monitor work 5 Getting started 6 Installing and replacing the batteries 6 Setting the date time and measurement units 6 Positioning the wrist cuff 7 Taking a blood pressure measurement 8 Recalling measur...

Page 2: ... observer using the cuff and stethoscope auscultation method within the limits prescribed by EN1060 3 Non invasive Sphygmomanometers Part 3 Supplementary requirements for electro mechanical blood pressure measuring systems The monitor s accuracy in measuring diastolic pressure was tested using the fifth Korotkoff sound method This manual contains important safety and care information and provides ...

Page 3: ...ng of arterial blood pressure It is not intended for use on extremities other than the wrist or for functions other than obtaining a blood pressure measurement Do not confuse self monitoring with self diagnosis This unit allows you to monitor your blood pressure Do not begin or end medical treatment based solely on the measurements of this device Consult a physician for treatment advice If you are...

Page 4: ...r dealer or designated collection point for proper disposal ABOUT BLOOD PRESSURE What is blood pressure Blood pressure is the force generated by the blood against the walls of arteries during cardiac contraction and relaxation e g the pumping action of the heart What are systolic pressure and diastolic pressure When ventricles contract and pump blood out of the heart blood pressure reaches its max...

Page 5: ...t during sleep Figure 4 below illustrates the variations over a single day with measurement taken every five minutes The thick line represents sleep time The rises in blood pressure at 4 PM A in the graph and 12AM B in the graph correspond to an attack of pain and sexual intercourse Beven Honour Stott Clin Sci 36 329 1969 HOW DOES THE BLOOD PRESSURE MONITORWORK This product uses the Oscillometric ...

Page 6: ... illuminate when the power is on Replace all the batteries at the same time it is dangerous to mix old and new batteries Contact your local waste disposal authority for instructions on how to dispose of used batteries Used batteries can be harmful to the environment and should not be thrown out with household trash Setting the date time and measurement unit It is important to set the clock before ...

Page 7: ... your left arm use your right wrist 2 Roll or push up your sleeve to expose the skin 3 Apply the cuff to your left wrist with your palm facing up Figure 6a 4 Position the edge of the cuff about 1 centimeter from the bottom of your palm Figure 6b 5 Fasten the wrist cuff around your wrist leaving no extra room between the cuff and your skin If the cuff is too loose the measurement will be inaccurate...

Page 8: ...aking a measurement Rapid movements or other activities may alter your reading Wait at least one hour before taking your blood pressure if you have just eaten a large meal Do not smoke or drink alcohol before taking your blood pressure Do not measure your blood pressure if you are under stress Wait at least 3 minutes between measurements This allows your blood circulation to recover For a meaningf...

Page 9: ...h so that it is parallel with your heart with the palm facing up 3 Relax your hand 4 Press the ON button Result After a few seconds the blood pressure monitor beeps and begins inflating the wrist cuff It then slowly deflates until there is another beep signifying that the measurement is complete Don t move from the first beep until the last to ensure a more accurate measurement Your systolic and d...

Page 10: ...ries Display is dim or will not light up shows on the display Batteries are exhausted Batteries are inserted incorrectly Batteries are low Replace with new batteries 6 Insert the batteries correctly 6 Replace with new batteries 6 Problem Symptom Check this Remedy Error message shows on the display 1 2 or 3 shows on the display 4 shows on the display 5 shows on the display 6 shows on the display A ...

Page 11: ... 5 5 oz with batteries Cuff circumference 13 5 19 5cm 5 3 7 7in Measuring range Pressure 30 280 mmHg 4 0 37 3 kPa Pulse 30 200 pulse min Settings are wrong No user memory Date and time are incorrect Measurement unit mmHgor kPa are incorrect No records display when is pressed The clock was not set or reset after installingnew batteries The measurement unit was not set or reset after installing new ...

Page 12: ...ments for electromechanical blood pressure measuring systems The CE mark further indicates that this blood pressure monitor meets the general requirements for electronic products as regards to resistance to electromagnetic interference Malfunctioning may however occur in the proximity of extremely strong electromagnetic fields In accordance with the Ordinance for Operators of Medical Products a te...

Page 13: ...00 120 140 160 180 200 220 M D D M s s Name Age Weight kg lbs Date Time 10 PM 10 PM 10 Oct 17 Oct SYS DIS MAP 158 90 110 155 95 112 85 90 8 0 10 7 13 3 16 0 18 7 21 3 24 0 26 7 29 3 2003 Oregon Scientific All rights reserved ...