background image

5

GB

LOW BATTERY WARNING

When  it  is  time  to  replace  batteries,  the  respective  low-battery
indicator  will  show  up  when  the  respective  channel  is  selected.
The  battery  level  of  the  main  unit  will  be  shown  on  the  indoor
temperature when it is running low.

HOW TO USE THE TABLE STAND OR WALL

MOUNTING

The main unit has a removable table stand, which when connected,
can support the unit on a flat surface. Or you can remove the stand
and mount the unit on a wall using the recessed screw hole.

As for the remote unit, it comes with a wall-mount holder and a
removable stand. Use either to hold the unit in place.

Main unit

     Wall-mount                     Table Stand

Remote unit
              Wall-mount              Table Stand

THE RESET BUTTON

This  button  is  only  used  when  the  unit  is  operating  in  an
unfavorable way or malfunctioning. Use a blunt stylus to hold down
the  button.  All  settings  will  return  to  their  default  values.

GETTING STARTED

Once batteries are placed in a given remote sensor unit, it will start
transmitting  information  at  40-second  intervals.

Also,  for  approximately  a  3-minute  duration,  the  main  unit  will
automatically search for signals once batteries are installed. Upon
successful  reception,  the  individual  channel  temperature  reading
will  be  displayed  on  the  top  line  and  the  respective  humidity
reading on the bottom line. The main unit will automatically update
its  readings  at  about  40-second  intervals.

3

1

2

4 3 3 M H z        C A B L E        F R E E

M A X

H I

M A X

TE MP

1

1

 R H

CHANNEL

MODE/SET

MEMORY

24 hr     OFF

TIME

Summary of Contents for BAR122HG

Page 1: ...mation in outdoor temperatures and relative humidity radio frequency RF controlled calendar clock clock display of 2nd time zone and dual daily alarms Also the main unit can support up to three remote sensors Other features include weekday display in four abbreviated languages four step crescendo alarm and interchangeable clock display modes MAIN FEATURES MAIN UNIT A B C G H 4 3 3 M H z C A B L E ...

Page 2: ...en the alarm time is displayed I TIME BUTTON Decreases the value of a setting J TIME BUTTON Advances the value of a setting K 24 hr OFF BUTTON Displays the alarm time or changes the alarm set time L ON OFF BUTTON TEMP RH ALARM Enables disables HI LO temp alarm and HI LO RH alarm M HI LO BUTTON TEMP RH ALARM Set the upper or lower temperature alarm limits of individual channels Confirms alarm setti...

Page 3: ... E RESET Returns all settings to default values F BATTERY COMPARTMENT Accommodates two AAA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units before doing so for ...

Page 4: ... compartment door BATTERY AND CHANNEL INSTALLATION REMOTEUNIT The remote thermo hygro sensor unit uses two 2 UM 4 or AAA size alkaline batteries Follow these steps to install replace batteries 1 Remove the screws on the battery compartment 2 Select the channel number on the CHANNEL slide switch 3 Select the temperature display unit on the C F slide switch 4 Insert the batteries strictly according ...

Page 5: ...mote unit Wall mount Table Stand THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are placed in a given remote sensor unit it will start transmitting information at 40 second intervals Also for approximately a 3 minut...

Page 6: ...displayed in the box under the kinetic wave DISCONNECTED SIGNALS If without obvious reasons the display for a particular channel goes blank press CHANNEL MEMORY to enforce an immediate search If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note that when the temperature falls below freezing point the...

Page 7: ...e Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Presseither CHANNEL MEMORY HI LO ON OFF TEMP RH AL THE COMFORT LEVEL ICONS The comfort level indicators COMFORT WET or DRY will tell you if the curent environment is comfortable too wet or too dry The comfort indicator will appear on the display when the follow ing conditions are satisfied Indicator displays on th...

Page 8: ...d 2 Press MEMORY once to display the maximum temperature and humidity and again the minimum temperature and humidity The respective indicators MAX or MIN will be displayed To clear the memory Press and hold MEMORY for 2 seconds Ifyoupress MEMORY now themaximumandminimumrecordings will have the same values as the current ones until different readings are recorded HOW TO USE CHANNEL 1 TEMPERATURE HU...

Page 9: ...e alarm If in another channel other than channel one is selected when the alarm activates the display will switch to channel 1 and the display will flash If left untouched the alarm will activate for a 1 minute Press CHANNEL MEMORY HI LO ON OFF to TEMP RH AL momentarily stop the alarm The alarm will activate again if the limit continues to exceed the set limit Note If a second limit is passed whil...

Page 10: ...l toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the button is pressed ABOUT RADIO RECEPTION The BAR122HG is designed to automatically synchronize its calendar clock once it is brought within range of the Frankfurt DCF77 radio signal When the BAR122HG is within range its radio control mechanism will override all manual settings When ...

Page 11: ... date are displayed in 24 HOUR clock format For the language display you can choose among English E German D French F and Italian I Weekday is in the usual sequence of Monday through Sunday For the 2nd time zone which is indicated by the ZONE icon enter the hour offset using the TIME and TIME buttons and the BAR122HG will calculate the second zone time accordingly If there is an item you do not wi...

Page 12: ...utton is pressed instead the alarm will be stopped and deactivated all together MAINTENANCE When handled properly this unit is engineered to give you years of satisfactory service Here are a few product care instructions 1 Do not immerse the unit in water If the unit comes in contact with water dry it immediately with a soft lint free cloth 2 Do not clean the unit with abrasive or corrosive materi...

Page 13: ...ressly approved by the party responsible for compliance could void the user s authority to operate the equipment R TTE Compliance Note This device complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directive if used for its intended use and that the following standard s has been applied Electromagnetic compatibility Article 3 1 b of the R TTE Direc tive Applied standards ...

Page 14: ...14 GB COUNTRIES RTTE APPROVAL COMPLIED Austria Belgium Denmark Finland France Germany Greece Italy Luxembourg Netherlands Portugal Spain Sweden UK and Ireland ...