background image

7

EN

HOW TO READ THE KINETIC WAVE

DISPLAY

The kinetic wave display shows the signal receiving status of the
main unit. There are three possible forms:

The unit is in searching mode.

Transmission data are securely
registered.

No signal received in search mode.

REMOTE SENSOR SCANNING

The unit can be set to automatically scan and display readings from
the remote sensors and indoor readings. When the remote-sensor
mode is active, the display will show the readings from one channel
for about 4-second and then proceed to the next channel display.

To activate the remote-sensor scanning mode:

Press and hold [CHANNEL] for 2-seconds.

To deactivate the remote-sensor scanning mode:

Press either [CHANNEL], [MEM], [HI/LO], [ 

 ], [

ON / OFF]

                                                                          (TEMP % RH AL)

THE COMFORT-LEVEL ICONS

The comfort level indicators COM, WET or DRY will tell you if the
current environment is comfortable, too wet or too dry.

The comfort indicator will appear on the display when the follow-
ing conditions are satisfied:

Indicator

displays

on the unit

COM

WET

Temperature

Range

20°C to 25°C
(68°F to 77°F)

-5°C -+ 50°C
(23°F - 122°F)

-5°C -+ 50°C
(23°F - 122°F)

Humidity

Range

40%RH-
70%RH

OVER-
70%RH

Below
70%RH

Shows that the

Current

Environment

Ideal range for
both relative
humidity and
temperature

Contains excess
moisture.

Contains
inadequate
moisture

No

Indicator

Less than
20°C( 68°F)
or More than
25°C (77°F)

40%RH
to
70%RH

No comment

DRY

Summary of Contents for BAA182HG

Page 1: ...display LCD for displaying weather forecast information in outdoor temperatures and relative humidity calendar clock clock display of 2nd time zone and dual daily alarms Also the main unit can support up to three remote sensors Other features include weekday display in four abbreviated languages crescendo alarm and interchangeable clock display modes MAIN FEATURES MAIN UNIT CLOCK ON ON OFF OFF ON ...

Page 2: ...ases memory data H CHANNEL BUTTON Toggles among the remote sensor channels CLOCK I ON OFF BUTTON Enables or disables the daily alarms J BUTTON Decreases the value of a setting K BUTTON Advances the value of a setting TEMP RH ALARM L ON OFF BUTTON TEMP RH ALARM Enables disables HI LO temp alarm and HI LO RH alarm M HI LO BUTTON TEMP RH ALARM Set the upper or lower temperature and humidity alarm lim...

Page 3: ...l user programmed settings to original factory set values F BATTERY COMPARTMENT Accommodates two 2 UM 3 or AA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units b...

Page 4: ...e alkaline batteries 4 Replace the battery compartment door and the table stand BATTERY AND CHANNEL INSTALLATION REMOTEUNIT The remote thermo hygro sensor unit uses two 2 UM 3 or AA size batteries Follow these steps to install replace batteries 1 Remove the screws on the battery compartment 2 Select the channel number on the CHANNEL slide switch 3 Select the temperature display unit on the C F sli...

Page 5: ...UTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are placed in a given remote sensor unit it will start transmitting information at 40 second intervals Also for approximately a 3 minute duration the main unit will automatically ...

Page 6: ...ECTED SIGNALS If without obvious reasons the display for a particular channel goes blank press CHANNEL MEM toenforceanimmediatesearch If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note that when the temperature falls below freezing point the batteries of outdoor units will freeze lowering their vol...

Page 7: ...g mode Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Presseither CHANNEL MEM HI LO ON OFF TEMP RH AL THE COMFORT LEVEL ICONS The comfort level indicators COM WET or DRY will tell you if the current environment is comfortable too wet or too dry The comfort indicator will appear on the display when the follow ing conditions are satisfied Indicator displays on the...

Page 8: ...ecked 2 Press MEM once to display the maximum temperature and humidity and again the minimum temperature and humidity The respective indicators MAX or MIN will be displayed To clear the memory Press and hold MEM for 2 seconds If you press MEM now themaximumandminimumrecordingswill have the same values as the current ones until different readings are recorded HOW TO USE CHANNEL 1 TEMPERATURE HUMIDI...

Page 9: ... the status of the alarm If in another channel other than channel one is selected when the alarm activates the display will switch to channel 1 and the display will flash If left untouched the alarm will activate for a 1 minute Press CHANNEL MEM HI LO ON OFF to TEMP RH AL momentarily stop the alarm The alarm will activate again if the limit continues to exceed the set limit Note If a second limit ...

Page 10: ...te time zone MODE 4 Hour Minute Day of the Week of second time zone Day Month of alternate time zone Each press on the MODE button will toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the ALARM button is pressed HOW TO SET THE CLOCK MANUALLY To set the clock manually hold MODE for three seconds The hour digits will blink Press or CLOC...

Page 11: ... arm or disarm an alarm by pressing the ON OFF CLOCK button When an alarm is armed it will go off at the set time The four step crescendo function allows the alarm to start off gently and step up its intensity every 20 seconds for four times Without interruption the alarm will go off for a total of two minutes If no key is pressed to turn off the alarm within these 2 minutes the alarm will go off ...

Page 12: ...he unit contains no user serviceable parts 5 Only use new batteries as specified in this instruction manual Do not mix new and old batteries as the old batteries may leak 6 Read this instruction manual thoroughly before operating the unit SPECIFICATIONS Temperature Measurement Main unit Indoor Temperature measurement Proposed operating range 23 0 F to 122 0 F 5 0 C to 50 0 C Temperature resolution...

Page 13: ...icular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures o Reorient or relocate the receiving antenna o Increase the separation between the equipment and receiver o Connect the equipment into an ...

Page 14: ...Should this not be possible contact our customer care department for assistance and a return material authorization No returns may be made without a return authorization Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased This warranty does not cover product subjected to abuse misuse accidental damage or tampering 2003 Oregon Scientific All rig...

Reviews: