background image

13

EN

NOTE ON COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause
undesired operations.

Warning:   Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.

FCC  :

NOTE:  This equipment has been tested and found to comply with
the limits for a Class  B digital device, pursuant to Part 15 of the FCC
Rules.  These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful  interference to radio communications.

However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:

o

Reorient or relocate the receiving antenna.

o

Increase the separation between the equipment and receiver.

o

Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.

o

Consult the dealer of an experienced radio/TV technician for
help.

Company Name: Oregon Scientific, Inc.

Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA

Telephone Number: 1-800-853-8883

Name and model number of the product: Weather Station
BAA182HG

CAUTION

— The content of this manual is subject to change without

further notice.

— Due to printing limitation, the displays shown in this

manual may differ from the actual display.

— The contents of this manual may not be reproduced without

the permission of the manufacturer.

CUSTOMER ASSISTANCE

Should you require assistance regarding this product and its

operation, please contact our customer care department at

800-853-8883 or via email at [email protected].

Summary of Contents for BAA182HG

Page 1: ...display LCD for displaying weather forecast information in outdoor temperatures and relative humidity calendar clock clock display of 2nd time zone and dual daily alarms Also the main unit can support up to three remote sensors Other features include weekday display in four abbreviated languages crescendo alarm and interchangeable clock display modes MAIN FEATURES MAIN UNIT CLOCK ON ON OFF OFF ON ...

Page 2: ...ases memory data H CHANNEL BUTTON Toggles among the remote sensor channels CLOCK I ON OFF BUTTON Enables or disables the daily alarms J BUTTON Decreases the value of a setting K BUTTON Advances the value of a setting TEMP RH ALARM L ON OFF BUTTON TEMP RH ALARM Enables disables HI LO temp alarm and HI LO RH alarm M HI LO BUTTON TEMP RH ALARM Set the upper or lower temperature and humidity alarm lim...

Page 3: ...l user programmed settings to original factory set values F BATTERY COMPARTMENT Accommodates two 2 UM 3 or AA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units b...

Page 4: ...e alkaline batteries 4 Replace the battery compartment door and the table stand BATTERY AND CHANNEL INSTALLATION REMOTEUNIT The remote thermo hygro sensor unit uses two 2 UM 3 or AA size batteries Follow these steps to install replace batteries 1 Remove the screws on the battery compartment 2 Select the channel number on the CHANNEL slide switch 3 Select the temperature display unit on the C F sli...

Page 5: ...UTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are placed in a given remote sensor unit it will start transmitting information at 40 second intervals Also for approximately a 3 minute duration the main unit will automatically ...

Page 6: ...ECTED SIGNALS If without obvious reasons the display for a particular channel goes blank press CHANNEL MEM toenforceanimmediatesearch If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note that when the temperature falls below freezing point the batteries of outdoor units will freeze lowering their vol...

Page 7: ...g mode Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Presseither CHANNEL MEM HI LO ON OFF TEMP RH AL THE COMFORT LEVEL ICONS The comfort level indicators COM WET or DRY will tell you if the current environment is comfortable too wet or too dry The comfort indicator will appear on the display when the follow ing conditions are satisfied Indicator displays on the...

Page 8: ...ecked 2 Press MEM once to display the maximum temperature and humidity and again the minimum temperature and humidity The respective indicators MAX or MIN will be displayed To clear the memory Press and hold MEM for 2 seconds If you press MEM now themaximumandminimumrecordingswill have the same values as the current ones until different readings are recorded HOW TO USE CHANNEL 1 TEMPERATURE HUMIDI...

Page 9: ... the status of the alarm If in another channel other than channel one is selected when the alarm activates the display will switch to channel 1 and the display will flash If left untouched the alarm will activate for a 1 minute Press CHANNEL MEM HI LO ON OFF to TEMP RH AL momentarily stop the alarm The alarm will activate again if the limit continues to exceed the set limit Note If a second limit ...

Page 10: ...te time zone MODE 4 Hour Minute Day of the Week of second time zone Day Month of alternate time zone Each press on the MODE button will toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the ALARM button is pressed HOW TO SET THE CLOCK MANUALLY To set the clock manually hold MODE for three seconds The hour digits will blink Press or CLOC...

Page 11: ... arm or disarm an alarm by pressing the ON OFF CLOCK button When an alarm is armed it will go off at the set time The four step crescendo function allows the alarm to start off gently and step up its intensity every 20 seconds for four times Without interruption the alarm will go off for a total of two minutes If no key is pressed to turn off the alarm within these 2 minutes the alarm will go off ...

Page 12: ...he unit contains no user serviceable parts 5 Only use new batteries as specified in this instruction manual Do not mix new and old batteries as the old batteries may leak 6 Read this instruction manual thoroughly before operating the unit SPECIFICATIONS Temperature Measurement Main unit Indoor Temperature measurement Proposed operating range 23 0 F to 122 0 F 5 0 C to 50 0 C Temperature resolution...

Page 13: ...icular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures o Reorient or relocate the receiving antenna o Increase the separation between the equipment and receiver o Connect the equipment into an ...

Page 14: ...Should this not be possible contact our customer care department for assistance and a return material authorization No returns may be made without a return authorization Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased This warranty does not cover product subjected to abuse misuse accidental damage or tampering 2003 Oregon Scientific All rig...

Reviews: