Service problems that appear to be major can often be solved easily. You can be your own 

troubleshooter by reviewing this guide. 

All other servicing should be done by an Oreck Approved Service Centre. 

All accessories and replacement parts are sold separately. To order, call Customer Care on 

0845 603 0153

or visit our website www.oreck.co.uk. Please have your model number 

from the data label on the bottom of the unit. 

Accessories  

Item 

Part Number  

Crystal Aroma

®

Carpet and Room Freshener 

CRYSTAL 

Oreck Dry Carpet

®

Cleaning System 

CARPETCSYS  

Item 

Part Number  

Dust Bag, 8 Pack, Saniseal

®

Hypo-Allergenic 

PK20008DW 

Belts, 3 Pack 

3BELTS  

  

H

 

S

 

I

 

L

 

G

 

N

 

E

Parts  

Replacement Parts  

Trouble-

shooting  

Problem

Check

What to do

Cleaner will not 

run.

•  Not plugged in properly. 

•  No electricity from wall 

socket.

socket.

•  Check electrical source – fuse or circuit  

breaker.

Cleaner does not 

pick up.

•  Filter Bag is full.

•  Nozzle or intake

clogged.

•  Belt is broken or 

stretched.

•  Brush is worn.

•  Bag tube clogged.

•  Bag pores are clogged 

•  Revolving brush not 

even at each end.

•  Clear obstruction. See “Stuffing or 

    Blockage” page 8.

•  Replace belt. See “Replacing 

   Worn Belt” page 6.

•  See “Adjusting or Replacing Brushroll” 

   page 7.
•  Clear obstruction. See “Stuffing or 

    Blockage” page 8.

•  Change bag. See “Replacing 

   Disposable Dust Bag” page 6.
•  Check that the brushroll is aligned 

   correctly. See “Adjusting or Replacing

   Brushroll” page 7. 

Unit still does not 

operate properly.

•  Contact Oreck for service.

Service Kit 

SERKIT35G

Dust Bags, 8 Pack, HEPA Odour Fighting

CCPK8OH

Fresh Air 

®

 Scented Tablets

AIRTABS

•  Replace Filter Bag. See “Replacing 

   Disposable Dust Bag” page 6.

Summary of Contents for XL3

Page 1: ...User s Guide Powerful Lightweight Upright Vacuum XL3 Important Read all instructions carefully and keep for future reference 76071 01 REV A UK VERSION ...

Page 2: ...or carry by Power Cord use Power Cord as a handle close door on Power Cord or pull Power Cord around sharp edges or corners Keep Power Cord away from heated surfaces Do not run appliance over Power Cord Do not unplug by pulling on Power Cord To unplug grasp the plug not the Power Cord Do not handle plug or appliance with wet hands Do not put any object into openings Do not use with any opening blo...

Page 3: ...ia 19 Housing 20 Cord Strain Relief Assembly 21 Harness 22 O Ring 5 2 10 3 9 4 20 7 12 15 17 14 18 13 8 1 6 16 11 19 21 Safety 2 General Warnings 2 Operation 3 Parts List 3 Assembling the Appliance 4 Operating the XL3 4 Operating Instructions 4 General Information 5 Disposable Dust Bags 5 Celoc Filtration System 5 The Belt 5 Lubrication 5 Maintenance 6 Replacing Disposable Dust Bags 6 Replacing Wo...

Page 4: ...se your vacuum cleaner on damp or wet surfaces This will cause damage to the vacuum cleaner and is dangerous to the user Damage caused by use on wet or damp surfaces is not covered under warranty 6 For optimal performance replace the belt every 6 months 7 Check the Disposable Filter Dust Bag at least once a month 8 DO NOT run the vacuum cleaner over the Power Cord The revolving brush could damage ...

Page 5: ...ry important for the effective operation of the cleaner If the belt becomes stretched or cut it will cause the revolving brush to stop completely or slow down See page 6 for replacing worn belt Note An extra belt is stored in the baseplate of your cleaner When buying replacement belts use ONLY ORECK genuine belts Belts other than Oreck belts will not operate the revolving brush correctly and may c...

Page 6: ... 7 8 9 10 6 7 8 8 10 11 12 13 14 15 WARNING Unplug Power Cord from electrical socket before servicing Remove the replacement belt from the storage channel on the vacuum base Remove the Belt Door by removing the Phillips screw located on side of Power Head Fold door away from the Power Head and lift it away Remove the belt from the motor drive shaft and brushroll pulley Loop the new belt over the b...

Page 7: ...and on a new brushroll this should be facing uppermost Refit the belt Refit the baseplate If a previous adjustment has already been made and bristle height does not extend above the baseplate a new brush assembly should be ordered or a Service Kit SERKIT35G Adjusting or Replacing Brushroll 16 15 16 16 17 18 19 WARNING Unplug Power Cord from electrical socket before servicing Replacing Edge Brushes...

Page 8: ...g tabs are locked in place Reattach Bag Spring Many times blockage occurs due to a full dust bag causing dirt When that happens the blockage will be at the top of the system starting in the area where the dust bag connects to the Connector Assembly Replacing Light Bulbs Maintenance WARNING Unplug Power Cord from electrical socket before servicing Remove the baseplate by removing 5 Philips screws R...

Page 9: ...Check What to do Cleaner will not run Not plugged in properly No electricity from wall socket socket Check electrical source fuse or circuit breaker Cleaner does not pick up Filter Bag is full Nozzle or intake clogged Belt is broken or stretched Brush is worn Bag tube clogged Bag pores are clogged Revolving brush not even at each end Clear obstruction See Stuffing or Blockage page 8 Replace belt S...

Page 10: ...RRANTIES FOR THIS PRODUCT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE WARRANTY PERIOD AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THIS PERIOD This limited warranty is in addition to your statutory and other legal rights UK EIRE DISTRIBUTOR Integrity Europe Ltd 32 Marsh Green Road West Marsh Barton Exeter EX2 ...

Page 11: ...11 ...

Page 12: ...eck Holdings LLC All rights reserved All word marks logos product configurations and registered trademarks are owned and used under the authority of Oreck Holdings LLC 76071 01 REV A 01 09 ECN R 9251 OK3174 DF ...

Reviews: