background image

6

To Adjust or Replace Brush

WARNING: Unplug cord from electrical

outlet before servicing.

fig. 17 To determine if the brush is worn, place a firm straight edge

across the nozzle opening. If brush bristles do not extend
beyond baseplate, brush should be adjusted.

fig. 18 Remove the baseplate by removing 5 screws. 

fig. 19 Remove the belt and brush roll from the housing.

fig. 20 Rotate both bearing assemblies at ends of brush roll to show

"OLD" and replace in the holding channels in the housing. 

NOTE: The bearing assembly setting marked "OLD" has a smooth
side. The one marked "NEW" has notches. When rotating bearings,
make sure both bearing assembly settings are the same and face up
when replacing the brush roll.

fig. 17 Reassemble the belt and the baseplate and check bristle height

above baseplate at each end of brush.

If a previous adjustment has already been made and bristle height does
not extend above baseplate, a new brush assembly should be ordered.

IMPORTANT: Unless the brush is worn as indicated above, both
bearings must be in the “NEW” position. When rotating, both
bearings must be in the “OLD” position. Unmatched settings will
cause damage to your machine.

Using An Oreck Fresh Air

®

Tab

fig. 21 Your ORECK XL vacuum cleaner has a special ORECK

FRESH AIR

®

tab pocket. This pocket is located inside the outer

bag in the area where the disposable paper filter bag attaches
to the intake tube. Insert tablet in pocket if desired.

Stuffing or Blockage

IMPORTANT: On plush and new carpets, stuffing may occur inside the
the intake tube and the lower tube assembly. This is due to excessive
fuzz and loose cuttings in the carpet. Stuffing could occur for the first
few cleanings until all the loose material is removed. Due to the high
efficiency of the cleaner, many older carpets will cause stuffing when
the cleaner is first used on them. If your vacuum cleaner does not pick
up properly, or makes unusual noise and the outer bag does not fluff up
or balloon open, follow these steps:

WARNING: Unplug cord from electrical

outlet before servicing.

fig. 22 Check for blockage at the mouth of the intake opening. If there

is blockage, remove it with long-nose pliers, a screwdriver or
coat hanger. If you can not reach the blockage, remove
baseplate (fig. 23).

fig. 24 If the blockage is not at the base, remove lower tube. Unhook

retainer spring, releasing bottom of bag. 

fig. 25 Twist lower collar counterclockwise to slide up. Pull tube out of

base. 

fig. 26 Check for blockage. If blockage is in the tube, remove with a

coat hanger.

fig. 27 If tube is not blocked, look into fan housing. Remove debris

with long-nose pliers, a screwdriver or coat hanger.

fig. 25 To reassemble, check O-ring on tube, and replace if damaged.

Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place. 

fig. 28 Make sure collar is not cross threaded on housing. Reattach

bag spring (fig. 24).

fig. 29 Many times blockage occurs due to a full dust bag causing dirt

to back down the air flow system. When that happens, the
blockage will be at the top of the system, starting in the area
where the dust bag connects to the connector assembly.

NOTE: If the above actions do not correct the problem, contact an
Oreck authorized service center or call the customer service center.
03-9540-0700

General Cleaner Care

At least once a month, check for and
remove excessive lint, string or hair
from revolving brush.

Wipe the outside of the cleaner with
a damp cloth. Also clean the
connector deflector assembly area,
base of cleaner and fan housing
area. If there is dust in the outer bag,
vacuum it or shake it out.

A little preventative maintenance will
keep your cleaner looking new and
will ensure continued cleaning effec-
tiveness.

CAUTION—Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor
Surfaces and Polished Floor Finishes

Use floor and floor finish manufacturer’s recommended methods of
cleaning. The metal strip on the base of the cleaner could be damaged
if used on concrete or abrasive surfaces, and, therefore, cause damage
to wood floors, soft (vinyl, asphalt tile, etc.) floor surfaces and polished
floor finishes. The roller brush may also scuff very soft finishes. Do not
operate the unit while in the upright and locked position. Do not let the
unit run while in any one stationary position for any period of time. Keep
the unit moving while in operation. 
Celoc

®

Hypo-Allergenic Filter System

The Celoc SMMS outer bag of your vacuum cleaner is high filtration
medical material designed to filter the smallest of dust particles. It is
important that the inside of the outer bag be cleaned. Vacuum the inside
of the outer bag or hand wash, turned inside out, with warm water, and
air dry. For best results, the Celoc SMMS outer bag should be replaced
once a year. The Celoc layered disposable inner dust bag must be
replaced once a month even if it is not full. Change it more often if it is
used in extremely dirty areas. Increase the cleaning power of your
vacuum by changing the bag often.

To Replace Filter Dust Bag

WARNING: Unplug cord from electrical
outlet before servicing.

BAG REMOVAL:

fig. 7

Unzip outer bag completely.

fig. 8

Pull bag cardboard collar to release bag dock door from
connector. Bag dock door will hinge downward.

fig. 9

Gently pull bag cardboard collar upward out of the bag dock.
Dust seal will close automatically.

BAG INSTALLATION:

fig. 10 Slide the cardboard collar completely onto bag dock door.

fig. 11 Firmly push bag dock door with both thumbs on indication point

until snap is heard.

How to Replace a Worn Belt

WARNING: Unplug cord from electrical

outlet before servicing.

fig. 12 Remove the replacement belt from the storage channel.

fig. 13  Remove the door by removing the hold down screw located on

side of power head.

fig. 14 Slide the door forward by prying open with a screwdriver or

coin.

fig. 15 Remove the belt from the motor drive shaft and brush roll

pulley.

fig. 16 Loop the new belt over the motor drive shaft. Place the

opposite end of the belt on the brush pulley. Rotate the brush
roll three (3) complete revolutions to ensure that no part of the
belt is overhanging the end of the motor drive shaft.

fig. 14 Replace the door by sliding it into the groove at the bottom of

the housing.

fig. 13 Replace the hold down screw and tighten.

Summary of Contents for XL2606HH

Page 1: ...E IMPORTANT SAVE THIS BOOKLET Includes Safety Warnings Warranty Operating Instructions Trouble Diagnosis Accessories XL2606HH HIGH SPEED UPRIGHT VACUUM CLEANER WITH CLEANING SYSTEM 75386 08 REV A No 1 for Easy Powerful Cleaning Since 1963 ...

Page 2: ...RE SIO NE HAS TA ESCUCHAR UN CHAS QUIDO DE SUJECI ÓN 3 6 4 Cord Dump 8 9 10 2 7 11 13 14 15 17 18 21 16 25 22 23 24 26 27 28 Connector Deflector Opening Retainer Spring Fan Housing O ring Intake Opening Intake Opening 19 OLD NEW Fan Housing Tube 1 5 12 28 20 TAB 2 ...

Page 3: ...the unit while in the upright and locked position Do not let the unit run while in any one stationary position for any period of time Keep the unit moving while in operation Do not allow to be used as a toy Close attention is necessary when used by or near children Use only as described in this manual Use only manufacturer s recommended attachments Do not use with damaged cord or plug If appliance...

Page 4: ...ntee Guarantee ORECK XL No 1 for Easy Powerful Cleaning since 1963 Hypo Allergenic Cleaner Plus Compact Barrel Cleaner Troubleshooting Guide WARNING Unplug cord from electrical outlet before servicing SAVE SERVICE CALLS CHECK THESE FIRST Is the disposable filter dust bag full Are pores of filter dust bag clogged with powder or fine dust Is anything clogging the revolving brush lower tube intake op...

Page 5: ...ve operation of the cleaner If the belt becomes stretched or cut it will cause the revolving brush to stop completely or slow down See instructions in the manual for replacing belt An extra belt is stored in the baseplate of your cleaner When buying replacement belts use ONLY ORECK genuine belts Belts other than ORECK belts will not operate the revolving brush correctly and may create undue stress...

Page 6: ...ig 24 fig 29 Many times blockage occurs due to a full dust bag causing dirt to back down the air flow system When that happens the blockage will be at the top of the system starting in the area where the dust bag connects to the connector assembly NOTE If the above actions do not correct the problem contact an Oreck authorized service center or call the customer service center 03 9540 0700 General...

Page 7: ... powerful and may pick up items which your old cleaner did not Please be careful to clean the floor of larger items which your old cleaner passed over such as pencils and small toys These items can cause a blockage in your machine ...

Page 8: ...Cleaning Since 1963 75386 08 REV A 2006 Oreck Holdings LLC All rights reserved All word marks logos product configurations and registered trademarks are owned and used 10 06 ECN R 8360 under the authority of Oreck Holdings LLC ...

Reviews: