12
Problem
Check
Solution
Unit does not
turn ON
• Power Cord
• Selector Switch
• Top Cover
•
ALCI Plug
• Plug in Power Cord
• Set Selector Switch for desired blower
speed.
• Make sure the top cover is securely closed
•
Press the red reset button each time you
plug in the ALCI safety device.
Truman Cell
light has turned
solid red.
Truman Cell
• A solid red light is a 30 day cleaning
reminder. Wash Collector Cell. Make sure
it is thoroughly clean and dry before
reinstalling.
Truman
C
ell
light is
blinking red
Truman Cell
• A fast blinking light indicates the power
supply has shut down due to arcing or
short circuit. The cell should be inspected
and cleaned, repaired, or replaced.
• A slow blinking light indicates the unit is
in Dry Mode.
Unit does
not remove
pollutants.
Truman Cell
• Clean the Truman Cell and make sure it is
completely dry before reinstalling.
• Truman cell may be damaged. Contact
Oreck for service.
Unit sparks,
crackles and
pops.
Truman Cell
• Sparking or popping noise (arcing) can
occur when a large particle is captured
in the Truman Cell. If the unit is arcing
excessively, the cell may be dirty. Try
cleaning the Truman Cell.
• If excessive arcing continues after proper
cleaning, the Truman Cell may be damaged
or wet. If damaged, contact Oreck for
service.
Trouble
-
shooting
Service problems that appear to be major can often be solved
easily. You can be your own troubleshooter by reviewing this guide.
All other servicing should be done by an Oreck authorized
service center.