Fig.2
DIMENSIONS
OEP80L
Model No.
A
B
C
D
E
10 9/16
"
10
"
5 1/2
"
4
"
13
"
F
G
4 1/2
"
"
12 9/16
H
I
4 3/16
"
2 3/4
"
J
7 5/8
"
OEP90L
OEP110L
OD50L
OD80L
OD90L
OD100L
OD110L
OD120L
OD series
OEP series
A
B C D
E
F
G
H
I
J
A
B C D
E
F
H
I
J
WIRING:
1. Run electrical cable as directly
as possible from the wall switch
to the unit.
2. Using approved connectors,
connect cable wires to fan wires:
black to black, white to white,
green wire to the ground
connection in the fans junction
box.
3. Do not allow cable to touch side
of unit after installation.
DUCTING
1. NEVER USE SCREWS to connect duct to termination
- USE TAPE ONLY making sure to not obstruct damper.
2. Termination duct pipe must exhaust outside the home.
3. Rigid sheet metal duct and the shortest path to the
outside is recommended.
MAINTENANCE
Power must be disconnected
during installation.
Always vent to the outdoors.
GRILLE
1. Grille can be installed after ceiling has been completed.
2. Pinch springs together then insert them carefully
through the interior slots in the housing.
NOTE: Never use gas, thinners or any other
chemicals for cleaning the ventilating
fan.
WARNING: Disconnect power before servicing.
Routine maintenance should be done every year.
1. Remove wash and clean the grill.
2. Using a soft cloth dampened with mild detergent,
remove any dirt from the unit then wipe to dry.
3. After cleaning, reassemble correctly.
1. Never allow water to get into the motor.
2. Never immerse plastic parts in hot water over 150 F.
Wiring Diagram
Light unit
Electric
Ballast
18W Lamp
18W Lamp
Fan unit
Motor
Condenser
Blue
White
Black
Earth Ground
Wiring box
Black
White
White
Black
Green
Green
terminal
Earth ground
Black
White
White
Black
Green
Earth ground
Power supply
(120V~60Hz)
Power supply
(120V~60Hz)
READ AND SAVE THESE INSTRUCTIONS