English
- 87 -
User Manual - Thermo X
Memory address
(ONLY when bUS=YES)
Adr
Upon initial start-up
procedure, default
parameters are
enforced an a new
address is generated
Settings guard
password
PAS
123
000 ÷ 999
For use in public
premises
Total number of hours
of output operation
Tot
000
000 ÷ 65535 (7 years)
Total number of hours
when output relay in
ON status
Battery charge status
bAt
100% ÷ 0%
The initial value
depends on the battery
charge
Display brightness
adjustment
(nt
8
0 ÷ 15
To enter advanced programming and change the parameters
1) Hold down
for 3 secs until the display reads “
rEG
”
2) Press or to select the desired value
3) Press
to confi rm
4) Repeat steps from 2) to 3) to change the remaining Advanced Programmimg
parameters
5) After confi rming the parameter “
(nt
” the device resumes the previous operating
status (Automatic, Manual or System Off)
Description of advanced programming parameters
TEMPERATURE-CONTROL METHOD (
rEG
)
The choice of the temperature-control method depends on the features of the system
it is applied to.
In
most cases ON/OFF temperature-control is recommended
(which is
the default choice), but
Proportional temperature control is preferable
in
premises with a high thermal drift (
large rooms, fan-coil systems, cast-iron
radiators
, etc)
The
Proportional
method can
only
be selected for the
WINTER-HEATING
mode.
Summary of Contents for Thermo X
Page 2: ......
Page 8: ...6 Manual de Uso Thermo X Espa ol APERTURA DE LA PUERTA FRONTAL TAMA O mm 123 0 93 5 33 5...
Page 33: ...Italiano 31 Manuale d Uso Thermo X CRONOTERMOSTATO DIGITALE Thermo X Manual d Uso...
Page 39: ...Italiano 37 Manuale d Uso Thermo X APERTURA SPORTELLINO FRONTALE DIMENSIONI mm 123 0 93 5 33 5...
Page 64: ...Italiano 62 Manuale d Uso Thermo X...
Page 65: ...English 63 User Manual Thermo X ELECTRONIC PROGRAMMABLE THERMOSTAT Thermo X User Manual...
Page 71: ...English 69 User Manual Thermo X FRONT FLAP OPENING DIMENSIONS mm 123 0 93 5 33 5...