(10).ABNORMITY AND SOLUTION
(11).
ELECTRICAL DIAGRAM.
DS 59160
DS 59190
Fault
Cause
Solution
Light on, but motor
does not work
The leaf blocked
Get rid of the blocking
The capacitor damaged
Replace capacitor
The motor jammed bearing damaged
Replace motor
The internal with of motor off or a bad smell from
the motor
Replace motor
Light does not work,
motor does not
work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord looses
Connect the wires as per the
electric diagram
Oil leakage
One way valve and the air ventilation
entrance are not tightly sealed
Take down the one way valve
and seal with glue
Le
akage from the connection of U-shaped
section and cover
Take U-shaped section down
and seal with soap or paint
Shake of the body
The leaf damaged and causes shaking
Replace the leaf
The motor is not tightly hanged
Lock the motor tightly
The body is not tightly hanged
Fixed the body tightly
Insufficient suction
The distance between the body and the
gas top too long
Readjust the distance
Too much ventilation from open doors or
windows
Choose a new place and
resemble the machine
The machine inclines The fixing screw not tight enough
Tighten the hanging screw and
make it horizontal
The hanging screw not tight enough
Tighten the hanging screw and
make it horizontal