Connect 24 V voltage to the control box as follows:
– Remove the connector (11) e.g. by prying off with a small screwdriver.
– Make sure that the electric wires are not live and then attach them to the connector.
– Push the connector and wires back into the counterpart.
– Pull any loose wire through the cable gland and out of the control box.
– Tighten the cable gland (12) nut.
PLEASE NOTE!
When connecting the voltage to the appliance, the solenoid valve will always be open for a moment.
– Turn on the water supply to the faucet.
– Check that the connections are watertight and that the faucet operates by placing your hand in front
of the photocell (14).
– Replace the control-box cover.
– In product no. 6104Z, 6105Z, 6114Z the water temparature can be regulated with the handle (25)
– Stick the instruction label supplied in a place where it can be seen easily.
After-flow time and recognition range (see Figure 3)
After-flow time is the period of time between the moment the photocell ceases to be activated and the
moment the water stops flowing. The recognition range is the greatest distance that an object can have
from the photocell to activate it and open the faucet. The after-flow time and sensing range have been
preset at the factory.
Sensing range
– Remove the control-box cover.
– Push the button (1).
– Position a piece of white paper (e.g. the installation instructions) vertically in front of the faucet,
at the
distance at which the photocell is intended to react
(e.g. at the outer edge of the wash-basin).
– Hold the paper at this distance. Water will start to flow after about 30 seconds.
Pull the paper away after the water flow has stopped!
– The sensing range is now set and stored.
– This information will not be lost from memory due to a power failure.
– Should the distance prove unsatisfactory, simply readjust by changing the position of the piece of paper.
– Replace the control-box cover.
Cleaning the Filter (see Figure 2)
If the water flow has decreased, this may be because the filter is clogged. Clean the filter as follows:
– Shut off the water supply to the faucet.
– Unscrew the strainer (18) from the valve housing.
– Clean the strainer under running water.
– Screw the strainer back.
Changing the temperature regulator (see Figure 4)
Troubleshooting
Symptom
Cause / Solution
Water flow from the outlet does
– The sensing range is too low
not stop, or stops after 2 minutes
– Check that the photocell is clean
– The solenoid valve is damaged
Water flow is low and weak
– Filter is clogged
No water comes out of the faucet
– Check the water supply to the control box
– The solenoid valve is damaged
– Power failure
– The photocell is covered or damaged
– 6105Z: the showerhead is not placed
properly in its wall bracket
14 (28)
GB
Summary of Contents for Electra 6100Z
Page 1: ...Installation and maintenance guide Oras Electra ...
Page 2: ......
Page 11: ...2 5 mm off 1 2 3 2 5 mm 5 4 17 4 5 6104Z 6105Z 6114Z 6215Z 6251FZ 11 28 ...
Page 27: ......