Installation Considerations
● Outlet may be installed in most two gang electrical boxes made from non-metallic
materials.
● Ensure the outlet fits the electrical box being used, including sufficient depth for
the hookup wires (2.5” minimum depth recommended)
● Install requirements for indoor and outdoor are different:
○ Outdoor installations may require an in-use weather cover if they are
exposed to damp, wet or other exposed environments. Confirm
requirements with applicable codes before operation.
Installation Height
Install Height
● Maximum height (indoor and outdoor): 60 in (1.52 m)
● Recommended height: ~45 in (~1.15 m)
● Minimum outdoor height: 24 in (0.6 m)
● Minimum indoor height: 18 in (0.45 m)
Please follow all National Electric Code
(NEC) requirements for your local
electrical code and building codes. If
you don’t know your local codes, please
contact a certified C-10 electrician to
perform the installation.
Maximizing Signal Reception
For cellular and Wifi connections please
check the mobile app during installation
to see if its signal strength is above 30%
signal.
Signal reception is negatively affected
by metallic enclosures, ensure that a
non-metallic enclosure is used.
Install Clearance Requirements