Oracle Talari T860 Hardware Guide
Connecting to the Console Port
The T860 APNA can be directly connected to a PC through a console port located on the
rear panel. In order to serial into your appliance via the console port, on your terminal
application you must select the specific serial line and use the following settings:
Speed (baud rate) - 115200
Data bits - 8
Stop bits - 1
Parity - None
Flow control - XOFF
Console cable - DB9-DB9
Troubleshooting
Basic Troubleshooting
The key to problem solving is to isolate the problem to a specific subsystem by comparing
what the appliance is doing to what it should be doing. The T860 APNA has LEDs and NIC
indicators on the front and rear panels for the indication of power, disk activity, Ethernet
activity, etc. These indicators can assist in isolating the problem to a specific subsystem.
Appliance Troubleshooting Basics
Problem
Resolution
Cannot ping the T860 APN appliance
Make sure the appliance has power. Confirm the device has a
management IP address assigned. Verify the management port has
link on the Talari and switch.
Ethernet port not forwarding traffic
Verify the switch has auto-negotiation enabled.
Verify the switch has the port enabled.
Confirm you connected to the correct port on the Talari.
Cannot access the Talari APNA Web
Console
Confirm you are using the correct IP address.
Confirm the management port of the T860 APNA is connected to a
switch and there is activity.
LEDs do not turn on
Check AC power source, Talari On/Off buttons.
Six beeps during boot process
Ensure that the Appliance’s memory is installed and available
Troubleshooting Bypass Mode (Fail-to-Wire)
The T860 APNA is equipped with a capability known as “bypass mode” or “fail-to-wire.”
This capability is designed to prevent a single point of failure. If there is a serious problem
with the T860 APNA, the bypass pair goes into bypass mode and forwards traffic through
as though the appliance were a wire.
A bypass pair may be configured as either “fail-to-wire” or “fail-to-block.” If a bypass pair is
configured for “fail-to-block,” bypass mode will never be activated, even if power is lost. Bypass
1 4