DIMM Failure Causes Other DIMMs To Be Disabled (CR 6929978)
DIMM Failure Causes Other DIMMs To Be Disabled (CR
6929978)
When a pair of DIMMs is disabled due to faults, BIOS disables other DIMMs to maintain a
valid configuration. For example:
■
In an 8-socket system, if a single DIMM is disabled due to faults, BIOS disables either 4 or
8 DIMMs depending on the socket number:
Faulted DIMM
Disabled DIMMs
D0 or D4
D0, D4, D1, D5, D8, D9, D12, D13
D1 or D5
D1, D5, D9, D13
D2 or D6
D2, D6, D3, D7, D10, D11, D14, D15
D3 or D7
D3, D7, D11, D15
D8 or D12
D0, D4, D1, D5, D8, D9, D12, D13
D9 or D13
D1, D5, D9, D13
D10 or D14
D2, D6, D3, D7, D10, D11, D14, D15
D11 or D15
D3, D7, D11, D15
■
In a 4–socket system, a faulted DIMM causes the BIOS to disable either two or four
DIMMs, depending on the socket number.
Faulted DIMM
Disabled DIMMs
D0 or D4
D0, D4, D1, D5
D1 or D5
D1, D5
D2 or D6
D2, D6, D3, D7
D3 or D7
D3, D7
D8 or D12
D8, D9, D12, D13
D9 or D13
D9, D13
D10 or D14
D10, D11, D14, D15
D11 or D15
D11, D15
Note -
When faulty happens on odd-numbered DIMMS, see
Numbered Pairs Results in DDR Training Failed on Entire Branch (CR7101624 and
Workaround
1. Identify the faulted DIMMs.
BIOS Issues
91
Summary of Contents for Sun Fire X4800
Page 1: ...Sun Fire X4800 Server Product Notes Part No E69641 07 July 2017 ...
Page 2: ......
Page 12: ...12 Sun Fire X4800 Server Product Notes July 2017 ...
Page 26: ...26 Sun Fire X4800 Server Product Notes July 2017 ...
Page 60: ...60 Sun Fire X4800 Server Product Notes July 2017 ...
Page 88: ...88 Sun Fire X4800 Server Product Notes July 2017 ...