Clear a Fault Manually
->
set /HOST/diag error_level=max
->
set /HOST/diag hw_change_level=max
Refer to the section on setting the SPARC host keyswitch state in the
Oracle ILOM
Administrator’s Guide for Configuration and Maintenance Firmware Release 4.0.x
for a
description of parameters and values.
4.
View the current values for settings.
Example:
->
show /HOST/diag
/HOST/diag
Targets:
Properties:
error_reset_level = max
error_reset_verbosity = normal
hw_change_level = max
hw_change_verbosity = normal
level = min
mode = normal
power_on_level = max
power_on_verbosity = normal
trigger = hw_change error-reset
verbosity = normal
Commands:
cd
set
show
->
Related Information
■
Clear a Fault Manually
When PSH detects faults, the faults are logged and displayed on the console. In most cases,
after the fault is repaired, the corrected state is detected by the server, and the fault condition
is repaired automatically. However, this repair should be verified. In cases where the fault
condition is not automatically cleared, you must clear the fault manually.
1.
After replacing a faulty FRU, power on the server.
Detecting and Managing Faults
39
Summary of Contents for SPARC T8-4
Page 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Page 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Page 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Page 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Page 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Page 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Page 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Page 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Page 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Page 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...