Remove a Fan Module
Related Information
■
“Remove a Fan Module” on page 148
■
“Install a Fan Module” on page 151
■
“Verify a Fan Module” on page 152
Remove a Fan Module
The fan module is a hot-service component that can be replaced by a customer.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause failure of server components.
1.
Locate the faulty fan module that you want to remove from the server.
■
“Rear Panel Components” on page 15
modules in the server.
■
“Determine Which Fan Module Is Faulty” on page 147
fan module.
2.
Determine if you can remove the fan module with the server running or not.
See
“Fan Module Configuration” on page 146
to determine if you can remove a fan module
with the server running or if you must shut down the server before removing a fan module.
■
If you can remove a fan module with the server running, go to
.
■
If you cannot remove a fan module with the server running, see
Power From the Server” on page 50
to power down the server before
continuing.
148
SPARC T8-4 Server Service Manual • January 2022
Summary of Contents for SPARC T8-4
Page 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Page 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Page 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Page 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Page 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Page 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Page 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Page 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Page 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Page 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...