Fan Module LED
Fan Module LED
Each fan module has a single Service Required LED.
Determine Which Fan Module Is Faulty
The following LEDs are illuminated when a fan module fault is detected:
■
System Service Required LEDs on the front panel and rear I/O module
■
Server Fan Fail LED on the front panel
■
Service Required LED on the faulty fan module
1.
Determine if the System Service Required LEDs are illuminated on the front
panel or the rear I/O module.
“Interpreting LEDs” on page 27
2.
Determine if the Server Fan Fail LED on the front panel is illuminated.
“Front Panel Controls and LEDs” on page 29
.
3.
From the rear of the server, check the fan module LEDs to identify which fan
module needs to be replaced.
The fan module Service Required LED is illuminated on the fan module that needs to be
replaced.
4.
Remove the faulty fan module.
“Remove a Fan Module” on page 148
Servicing Fan Modules
147
Summary of Contents for SPARC T8-4
Page 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Page 2: ......
Page 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Page 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Page 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Page 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Page 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Page 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Page 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Page 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Page 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Page 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...