Environmental Requirements
Description
Value
Maximum server configuration specification under nominal temperature and
voltage conditions:
(Four 3.6 GHz T5 Processors, with sixty-four 32 GB DDR4 DIMMS, 8 HDD
and 16 I/O cards)
Idle input power
2124 W
Peak AC input power (running SpecJBB)
4386 W
Minimum server configuration specification under nominal temperature and
voltage conditions
(Two 3.6 GHz T5 Processors, with 32x 16GB DDR4 DIMMS, no HDD and no
I/O cards)
Idle input power
1023 W
Peak AC input power (running SpecJBB)
1915 W
†
Actual amperage draw may exceed rating by no more than 10%.
Note -
The maximum operating input current values are based on the formula P / (V *0.90),
where P = maximum operating input power and V = input voltage. For example: 620W / (100V
* 0.90) = 6.89A You can use this formula to calculate the maximum operating current at your
input voltage.
Caution -
Use only the power cords provided with the server.
Related Information
■
“Powering On the Server for the First Time” on page 65
■
“Physical Specifications” on page 17
■
“Environmental Requirements” on page 19
■
“Airflow Precautions” on page 21
Environmental Requirements
This topic includes these specifications:
■
Temperature, humidity, and elevation
Confirming Specifications
19
Summary of Contents for SPARC T7-4
Page 1: ...SPARC T7 4 Server Installation Guide Part No E54993 04 March 2017 ...
Page 2: ......
Page 8: ...8 SPARC T7 4 Server Installation Guide March 2017 ...
Page 10: ...10 SPARC T7 4 Server Installation Guide March 2017 ...
Page 22: ...22 SPARC T7 4 Server Installation Guide March 2017 ...
Page 28: ...28 SPARC T7 4 Server Installation Guide March 2017 ...
Page 64: ...64 SPARC T7 4 Server Installation Guide March 2017 ...
Page 86: ...86 SPARC T7 4 Server Installation Guide March 2017 ...