Install the PS Backplane
b.
Push the cover a little towards the front of the chassis.
c.
Push the tooth at the bottom of the cover to clear the edge of the power
supply cage.
d.
Lift the cover out of the chassis.
8.
Remove the four bus bar screws that secure the motherboard to the PS
backplane.
9.
Disconnect the AC cables from PS backplane.
Tilt the PS backplane to access the cable connectors.
10.
Lift the PS backplane out of the chassis.
11.
Install a new PS backplane.
“Install the PS Backplane” on page 165
Related Information
■
“Install the PS Backplane” on page 165
Install the PS Backplane
1.
Remove the PS backplane.
“Remove the PS Backplane” on page 163
.
2.
Unpack the replacement PS backplane and place it on an antistatic mat.
3.
Hold the PS backplane at the end of the power supply cage at an angle, and
connect the AC cables to the AC connectors on the PS backplane.
Ensure that each AC cable is connected to the appropriate connector. You must connect the AC
cable on the right to the AC connector on the right, and connect the AC cable on the left to the
AC connector on the left.
4.
Insert the PS backplane into position (panel 1).
Servicing the PS Backplane
165
Summary of Contents for SPARC T5-2
Page 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Page 2: ......
Page 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Page 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Page 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Page 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Page 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Page 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Page 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Page 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Page 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Page 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Page 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Page 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Page 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...