Note: For Bricks that have five-platter drives, the maximum ambient operational
temperature from 7000 feet to 10,000 feet is 95°F (35°C).
System Acoustics
Acoustics for a Pillar Axiom 600 system that comprises the following components
were tested to ISO 7779 by standard specifications:
● One Pilot
● One NAS Slammer
● Three Bricks
Such a system generates an acoustic level that is no greater than 70 dBA.
Table 51 System acoustics specification
Acoustic level (tested to ISO7779)
Does not exceed 6.5 Bels under normal conditions, which is:
● 73.4°F (23°C) ambient
● All fans operational
● No fault conditions
The acoustic level will increase under fault conditions.
System Random Vibration Specifications
Table 52 System random vibration specifications
Mode
Force
Frequency
Time
Operational
0.1 G RMS
3–100Hz (X, Y, and Z axis)
15 minutes
Non-operational
Administered using the Telcordia GR-63 CORE test
specifications. Tested with the rack inside a shipping crate.
Appendix C Pillar Axiom Hardware Specifications
About Pillar Axiom 600 Hardware Specifications
189