Install the Fan Tray
See
“Install the Fan Tray” on page 244
.
Related Information
■
“Rotate the Drive Cage to the Service Position” on page 71
■
“Install the Fan Tray” on page 244
Install the Fan Tray
Perform this task when you have previously removed the fan tray.
1.
If you previously removed the PSU and air ducts or raised the drive cage,
complete these prerequisites, as necessary, in this order.
See:
■
“Install the Air Duct” on page 236
■
“Install the PSU Duct” on page 240
■
“Secure the Drive Cage” on page 241
2.
Move any loose cables so that they are against the server walls.
Caution -
The fan tray goes inside the latch line of the cable pass through. Take care when
installing the fan tray so that the cable pass through is not damaged or unseated.
3.
Install the fan cage bracket, being careful to avoid damage to any mother
board components that are near the end of the bracket that gets secured to the
motherboard.
Caution -
The fan tray sits on top of the cable pass through. The cable pass through needs to be
properly seated when installing the fan tray. If not, damage may occur to the latch.
4.
Align the fan tray to where it installs into the server.
Two arrows on the top of power supply bay show where the fan tray aligns. Holes in the base of
the tray need to match up with fan connectors. If necessary, rotate the tray 180 degrees to align.
5.
Slowly lower the fan tray into the server.
Verify that the fan tray is properly seated, and the top surfaces of the fan tray are flush with the
server.
244
Netra SPARC S7-2 Server Service Manual • February 2017
Summary of Contents for Netra SPARC S7-2
Page 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Page 2: ......
Page 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...