Remove the Drive Backplane
4.
Use the Oracle ILOM
faultmgmt
shell to identify the faulty component.
“Identify Faulted Components” on page 27
Check the
Fault class
and
Description
fields for more information.
5.
If the drive backplane is faulty, replace it.
“Remove the Drive Backplane” on page 119
6.
If you are unable to determine if the drive backplane is faulty, seek more
information.
“Detecting and Managing Faults” on page 25
Related Information
■
“Preparing for Service” on page 43
■
“Remove the Drive Backplane” on page 119
■
“Detecting and Managing Faults” on page 25
Remove the Drive Backplane
Removing the drive backplane is a cold-service operation. You must power off the server before
you remove the drive backplane.
Caution -
This procedure requires that you handle components that are sensitive to ESD, which
can cause server components to fail.
1.
Prepare for service.
“Preparing for Service” on page 43
.
2.
Tilt and pivot the air filter away from the server.
“Remove the Filter” on page 79
.
3.
Complete these prerequisites in this order.
See:
■
“Remove a SAS Drive” on page 89
Remove all drives.
■
“Rotate the Drive Cage to the Service Position” on page 71
Servicing the Drive Backplane
119
Summary of Contents for Netra SPARC S7-2
Page 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Page 2: ......
Page 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...