Servicing the Battery (CRU)
116
Oracle Server X6-2 Service Manual • June 2016
d.
Reconnect the power cords to the server power supplies and reconnect the
data cables.
See
“Reconnect Data Cables and Power Cords” on page 193
e.
Power on the server.
See
“Power On the Server” on page 194
.
Verify that the Power/OK status indicator is steady on.
Servicing the Battery (CRU)
The battery maintains system time when the server is powered off and a time server is
unavailable. If the server fails to maintain the proper time when the server is powered off and
not connected to a network, replace the battery.
Caution -
Ensure that all power is removed from the server before removing or installing
the battery. You must disconnect the power cables from the system before performing these
procedures.
This section covers the following procedures:
■
“Remove the Battery” on page 116
■
“Install the Battery” on page 117
Related Information
■
“Extend the Server to the Maintenance Position” on page 56
■
“Remove the Server Top Cover” on page 60
Remove the Battery
1.
Prepare the server for service.
a.
Power off the server and disconnect the power cords from the power
supplies.
See
“Powering Down the Server” on page 51
.
b.
Extend the server to the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 56
.
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...
Page 284: ...284 Oracle Server X6 2 Service Manual June 2016 ...