COMMISSIONING THE UNIT
To commission the desktop paging system we must send configurations to it via an Ethernet connection. Accomplishing this
requires a PC equipped with a network card and connected to the UMX-03/0 unit through a switch or directly using a network
cable. The PC must have the
P.A. Manager
software installed.
1. Place the battery (see section
) and insert the cards required by the installation in the UMX-
03/0 (see section
2. Make the connections between units.
3. Apply power to the units.
4. Via the software, configure the parameters of the UMX-03/0 and the cards contained therein.
5. Send the configurations to the unit.
11.1.
Configuration of the UMX-03/0 network addresses
In order to be able to send configurations, the network addresses established from the configuration software and those of the unit
must match.
The network configurations of the unit may be modified directly from the front panel if an Administrator user access level is availa-
ble. To change the user, follow the section
11.1.1.
Changing the IP address
1.
Use the
/
navigation keys to select the settings
menu ( ).
2.
Using the
/
keys select
IP (10.1.1.1)
and press
OK
.
3.
Use the
or
keys to enter the desired digit (from 0 to
9 and blank space).
Move to the next digit using the
or
navigation keys.
(for example, to enter number 24
enter a blank space, 2, 4)
4. To finish press
OK
.
11.1.2.
Changing the Netmask
1.
Use the
/
navigation keys to select the settings
menu ( ).
2.
Using the
/
keys select
NETMASK (255.0.0.0)
and
press
OK
.
3.
Use the
or
keys to enter the desired digit (from 0 to
9 and blank space).
Move to the next digit using the
or
navigation keys.
4.
To finish press
OK
.
11.1.3.
Changing the Gateway
1.
Use the
/
navigation keys to select the settings
menu ( ).
2.
Using the
/
keys select
GATEWAY (0.0.0.0)
and press
OK
.
3.
Use the
or
keys to enter the desired digit (from 0 to
9 and blank space).
Move to the next digit using the
or
navigation keys.
4.
To finish press
OK
.
WARNING
.
To send configurations to the unit requires having the unit and the PC within the same IP address
range. The unit's network addresses and those set via the configuration software must match.
By default, the network configurations of the unit are the following:
IP ADDRESS: 10.1.1.1
NETMASK:
255.0.0.0
GATETEWAY: 0.0.0.0 (without Gateway)
If you wish to assign a different network address to the UMX-03/0, other than the one established by default, refer
to the following section
11.1. Configuration of the UMX-03/0 network