Class D wall-mounted amplifier
with IP connection
IF-7WDCETH
4ETH
3.
Click on
Network
.
4.
Modify
the
desired
network
settings
(
IP
,
Netmask
and
Gateway
)
and click the
Change
Network Settings
button
to apply the changes.
The equipment will restart
automatically.
6.
SYSTEM ALARMS
The equipment has several alarm systems that indicate that a failure has occurred in any element of the public address system:
GENERAL FAULT
indicator light: Front yellow LED. It lights up when the equipment receives one or more alarms from the
system, or when it generates an alarm itself.
SYSTEM FAULT
indicator light: Front yellow LED. It lights up when the equipment detects an internal error.
Audible alarm indicator (buzzer)
: Intermittent beep. The equipment has a buzzer that generates an acoustic indication each
time it receives an alarm. The acoustic indication, a beep of 10 seconds duration, is repeated periodically every 20 seconds. The
buzzer can be activated or deactivated via the
Call Point
or
Call Point Configurator
software.
It is possible to activate the buzzer for the
SYSTEM FAULT
alarm. To do this, set the internal jumper
JP1
to the
ON
position.