6 CLEANING
Malfunction
Cause
Remedy
Equipment will not turn
on.
Plug is not plugged in.
Power switch is in the off
position.
Main power fuseblown.
Plug the Power cord into
appropriate socket.
Switch the power on
Replace the fuse.
There is Power but the
rollers are not running
after the hot button is
pressed.
Emergency switch is engaged.
Safety cover is not closed. Guide
table is not installed correctly.
Blown motor fuse.
Disengage the mergency
switch.
Close the safety cover to
active the safety switch.
Property installs the paper
guide so that the safety switch
is activated.
Replace the motor fuse.
The unit is not
heating up.
The equipment is on the COLD
mode.
Set temperature is lower than the
room temperature.
Switch to HOT mode.
Raise the temperature
according to the recommended
film temperature.
The laminated
document is rippled.
Top foil is rippled.
Bottom foil is rippled.
Loosen the top roll foil
tension.
Loosen the bottom roll foil
ntension.
Bad lamination quality.
The main roller temperatures are
too high or too high speed .
Raise the roller temperatures
and lower the lamination
speed.
OPUS RolLAM 380 • User guide
GB
11
If you do not clean the rollers regularly the laminating foil can stick and damage the
rollers and cause unsatisfactory lamination and damage the equipment. You should
clean the rollers after and before starting a new project.
Note! Before clearing turn off the laminator and unplug it from the socket.
•
Clean the rollers every time after use.
•
Do not try to clean the rollers during operation.
•
Use only the recommended materials, others can damage the rollers.
After finished work reduce the tension on the foil with tension handle. If the tension
is too tight, the foil can be stretched and damage the new project.
7 MAINTENANCE