background image

Installation and operating instructions

4. Installation and commissioning

Step 1: 

Disconnect the system from the power supply.

Step 2: 

Connect the power unit and mount it in the flush-mounted box.

CAUTION

 – Optional protective cap! 

 

The plug-on, transparent protective cap included in the delivery is used  
to protect the installed device from dirt (dust, plaster, paint, etc.) during  
construction and renovation work. The protective cap must be placed on  
the installed OPUS BRiDGE switch, if the switch frame and rocker switches  
are not mounted!
OPUS BRiDGE can be operated with the protective cap in place.

Step 3:

 Plug the switch frame and retaining frame onto the  

power unit and fix it in place using two screws.

CAUTION

 – Screws for retaining frame!

 

Only use the self-tapping screws supplied to fix the switch and retaining 
frames.
Tighten the screws by applying a maximum torque of 0.7 Nm.  
Otherwise, there is a risk of damaging plastic parts.

Step 4: 

Plug the control unit onto the power unit.

CAUTION

 – Disassembly of the control unit!

 To dismantle the control unit, place a screwdriver at each corner in turn  
and lift off the control unit slowly and evenly. 

Do not bend or damage the electrical 
connection pins of the control unit!

Step 5:

 Attach rocker switch(es) to suit local operation:  

Series rockers 

   Wall trans roller shutter / louvre 

OR rocker panel 

  Roller shutter/ louvre

Step 6: 

Cancel voltage disconnection and configure the OPUS BRiDGE  

individually using the OPUS ConfigTool, if required. 

5. Reset to factory settings

press and hold 

T1 + T2 

(10 s)

operating condition

reset to factory 

settings

operating condition

power unit

control unit

wind 

sensor

power unit 

(rear view)

switch frame

retaining 

frame

Summary of Contents for 563.031

Page 1: ...en die Jalousie auch nach Loslassen der Wippe f r die maximale Fahr zeit Diese betr gt im Auslieferzustand 120 Sekunden und die Rotationszeit f r Jalousiebetrieb betr gt 2 Sekunden Beide Werte k nnen...

Page 2: ...rauben fixieren ACHTUNG Schrauben Halterahmen Zur Fixierung von Schalter und Halterahmen nur die mitgelieferten selbst schneidenden Schrauben verwenden Schrauben mit einem maximalen Drehmoment von 0 7...

Page 3: ...tsteuerung Typ 1 unidirektional F6 03 01 Wippenschalter mit 4 Wippen f r Lichtsteuerung Typ 1 unidirektional F6 05 00 Windwarner unidirektional F6 05 02 Rauchwarnmelder unidirektional F6 10 00 Fenster...

Page 4: ...roller shutter louvre moves for the maximum movement time even after the rocker is released This is 120 seconds in the as delivered state and the rotation time for louvre operation is 2 seconds Both v...

Page 5: ...e the self tapping screws supplied to fix the switch and retaining frames Tighten the screws by applying a maximum torque of 0 7 Nm Otherwise there is a risk of damaging plastic parts Step 4 Plug the...

Page 6: ...idirectional F6 03 01 Rocker switch with 4 rockers for light control type 1 unidirectional F6 05 00 Wind alarm unidirectional F6 05 02 Smoke detector unidirectional F6 10 00 Window and door handle uni...

Page 7: ...rijdt het rolluik de jaloezie ook na het loslaten van de wipper voor de ma ximale tijd Die bedraagt in afleveringstoestand 120 seconden en de rotatietijd voor het jaloeziebedrijf bedraagt 2 seconden D...

Page 8: ...roeven bevestigingsframe Gebruik alleen de meegeleverde zelftappende schroeven om afdekraam en bevestigingsframe te bevestigen Haal de schroeven aan met een maximaal draaimoment van 0 7 Nm Anders best...

Page 9: ...1 Wipschakelaar met 4 wippers voor lichtregeling type 1 unidirectioneel F6 05 00 Windsensor unidirectioneel F6 05 02 Rookmelder unidirectioneel F6 10 00 Venster en deurgreep unidirectioneel D5 00 01 V...

Reviews: