CP90-25P-M/C-72
Ref. 1896-SU-01-D
Page 34
AcquisitionMode
Description: This feature controls the acquisition mode of the device.
Value: Continuous
Value: SingleFrame
Value: CoaxPress
Length: 4
Access Mode: RW
AcquisitionStart
Description: This feature starts the Acquisition of the device.
Length: 4
Access Mode: RW
AcquisitionStop
Description: This feature stops the Acquisition of the device at the end of the
current Frame.
Length: 4
Access Mode: RW
Maximum: AcquisitionFrameRate
Description: Frame rate in Hz.
Minimum: 16
Maximum: 72
Unit: Hz
Length: 4
Access Mode: RW
Maximum: ExposureTime
Description: Sets the Exposure time (in microseconds) when ExposureMode is
Timed. This controls the duration where the photosensitive cells are exposed to
light.
Minimum: 98
Maximum: Depends on Frame rate
Unit: us
Length: 4
Access Mode: RW