8 Trouble Shooting
Problem
Lösung
After turning on the device, message
„Erroneous configuration data, default
values loaded. Press any key to con-
tinue...“
is shown.
The cause of this message is probably a hardware defect.
If the problem occurs again, please replace the device.
Touch any button to continue, make the necessary ad-
justments, and store the configuration. Turn the device off
and on. If the same message is shown again, the cause of
the problem is a hardware defect. Please replace the de-
vice.
When storing the configuration by use of
main menu entry
„Store Configuration“
,
message
„Storing configuration failed“
is
shown.
The cause of this message is probably a hardware defect.
Please retry to store the configuration. If the same mes-
sage is shown again, the cause of the problem is a hard-
ware defect. Please replace the device.
I have made configuration adjustments,
but when I turn off and again on the de-
vice, they are lost.
Execute main menu function
„Store Configuration“
, after
you have made adjustments. Only this way any manual
changes are held of power down.
The shown image flickers from time to
time, the image is flawed.
Please make sure that the video cable is correctly
shielded. For shielding, the ground wire (pin 1 (GND) on
the video connector) must be used.
Check if the shielding is correct at the video source and
the FSU211.
The image flickers continuously, contours
are shown blotted, a bright vertical bar is
visible.
Adjust the image sampling phase.