EP783/EP783S/EP783L/OPX5000/TX783L/TX783S
Confidential
4-0
4. Uniformity
Procedure
- Full white pattern
- Use CL100 to measure brightness values of
P1~P9 (see image: full white).
- Follow the Uniformity formula to calculate
average values.
☼ Uniformity Formula
ANSI Uniformity = Avg. (P1, P3, P7, P9) / P5 X100%
Criteria
- 65 %
4-11 Network Function Test
1. Read Projector IP
(1) Press “Menu” to enter OSD Mode.
(2) Select “RS232” under “SETUP”, choose “Network”
then press “Enter”.
(3) Write down the IP address: 10.0.50.100.