8-2
EP757
SERVICE MANUAL
Introduction Fundamental Principle Mechanical Construction Procedure of Disassembly Function of Boards Specifications
Troubleshooting
Function Test and Alignment Procedure
Firmware Upgrading Procedure DDC Key-In Procedure Appendix
8-1 Test Equipment
IBM PC with XGA resolution (Color Video Signal & Pattern Generator)
VCR with Multi-system(NTSC/PAL/SECAM)
Chroma meter Minolta CL-100
Hi-Pot
8-2 Test Condition
Circumstance Brightness : Dark room less than 60 lux
Inspection Distance : 2.0m
Screen Size : 60 inches diagonal (wide)
Before function test and alignment, each H50 should be run-in and warmed-up for at least 30
minutes with following conditions.
1.) In room temperature
2.) With cycled display colors (R,G,B,White)
3.) With cycled display modes
640 x 350 (H=31.5 KHz, V=70 Hz)
640 x 400 (H=31.5 KHz, V=70 Hz)
640 x 480 (H=37.5 KHz, V=75 Hz)
720 x 400 (H=31.5 KHz, V=70 Hz)
800 x 600 (H=53.7 KHz, V=85 Hz)
800 x 600 (H=37.9 KHz, V=60 Hz)
1024 x 768 (H=48.4 KHz, V=60 Hz)
1024 x 768 (H=68.7 KHz, V=85 Hz)
Test Display Mode & Pattern (Refer to 8-3.1 & 8-3.2)
Function Test and Alignment Procedure