23
9.2
Default Settings 2: Read Options, Trigger, Buzzer, LED settings
Parameter
Default Settings
Setting the number of characters
Fixed length OFF all codes
Read mode
Multiple read
Inter-character gap check (NM-7)
Character *1 > Inter-character gap
Multiple columns read (barcode only)
Disabled
Trigger switch
Enabled
Read time
2 seconds
Buzzer durations
200 msec
Buzzer tone
3kHz
+
2.5kHz
Buzzer loudness
Loud
LED indicator duration
200 msec
9.3 Default Settings 3: Communication settings
Parameter
Default Settings
Device address
Bluetooth device
Data memorizing
Disabled
Trigger connection
Disabled
Press trigger switch time to connect
Disabled
Press trigger switch time to disconnect
Disabled
Auto disconnect
Disabled
Auto reconnect
5 minutes
ACK/NAK No
Handshake
ACK/NAK Timeout
1 second
Wireless
Communication
Settings
PIN Code
Enabled (last 4 digits of the BD address)
Auto connect
Enabled
Authentication
Enabled (authentication if not paired)
Bluetooth
Connection
Setting
Encryption Disabled
10
.
Menu Barcodes
This section contains the menu barcodes of the OPI-4012 default settings.
Other menu labels are listed in the Universal Menu Book, such as Code options, String options, Read options, and Indicator
options.
10.1 Setting Method
There are two ways to configure the settings:
Setting 1. Scanning CODE39 barcodes:
To set the required options, proceed as follows: Scan the Set label, the required label, and the END label in sequence.
* If several labels in the same option are read, the last label read is enabled.
Setting 2. Scanning QR code:
This needs to scan directly without reading the “SET” and “END” labels.
Summary of Contents for OPI-4012