21
Firmware version 1.10 - Document version 1.06 - eng
LTDVE1CH-40F | INSTRUCTIONS MANUAL
Figure 10: example schematic #1
As shown, the power and logic supplies are derived from a common power supply.
If required by the application, a safety switch may be included in the circuit to cut off supply to the
power stages in order to protect the end user from photo-biological hazard. That switch would be
appropriately placed on the machine chassis.
The camera is triggered by the controller using the available synchronization output. Generally, it is
not possible to provide the details of the connections to the cameras because these are often vendor
specific. Please see the camera hardware manual for more information.
13.2. Wiring example #2: camera triggers controller
Figure 11: example schematic #2
the controller is driven by one input
trigger coming from a camera, powers one light and triggers a second camera.
Figure 11: example schematic #2
As shown, the power and logic supplies are derived from a common power supply.
If required by the application, a safety switch may be included in the circuit to cut off supply to the