When at least one error is present, the LED is instantly switched OFF and the illuminator enters the
error signaling routine, that continues until error(s) persist. The electronics automatically re-starts
normally operation in case of error resetting.
Particular attention must be paid to error code E1. This means that the LED board on the back of
the illuminator has reached a too high temperature. This can be caused by:
➢
Environmental temperature > 40°C
➢
Ventilation not present
➢
Temperature of the attaching mechanics too high
10.7 Optical layout and performances
LTBRZ3 Series is composed by 12 high-power LED sources, disposed as a linear array. Illumination
area has dimensions 295 x 25 mm. Led array is covered by a plastic protection window.
The series can be equipped with different options, detailed below.
10.7.1 Led color options
LTBRZ3 series offer a selection of different led colors ranging from visible to infrared. Five colors
are available as default, others are upon request
.
Option
Color
Peak wavelength
FWHM
Color temperature
-B
Blue
470 nm
25
-
-G
Green
530 nm
35
-
-R
Red
630 nm
20
-
-IR
Infrared
860 nm
40
-
-W
White
-
-
6500 K
Table 16: LED color options
.